Power
Note
Providing power levels either below or above the stated range is not recommended.
For your protection, the fuse is set to break if the input voltage exceeds 33 VDC.
Note
Environment
The front bezel is compliant with NEMA4 and IP65.
Note
Safety
For UL and other safety certifications, refer to the product label or the
Note
Product Certification

Electromagnetic Compatibility

Getting Started with the TPC-22xx
Input voltage ...........................................18–32 VDC
Operating temperature ............................–20 to 60 °C (–4 to 140 °F)
Storage temperature ................................–20 to 60 °C (–4 to 140 °F)
Humidity .................................................40 °C @ 10 to 95% relative
Vibration .................................................2 grms (5 to 500 Hz)
Maximum altitude...................................2,000 m
Pollution Degree .....................................2
Indoor use only.
This product is designed to meet the requirements of the following
standards of safety for information technology equipment:
IEC 60950-1, EN 60950-1
UL 60950-1, CSA 60950-1
section.
This product meets the requirements of the following EMC standards for
information technology equipment:
EN 55024 (CISPR 24); Immunity
EN 55022 (CISPR 22); Class A Emissions
EN 55011 (CISPR 11); Class A Emissions
AS/NZS CISPR 11; Class A Emissions
AS/NZS CISPR 22; Class A Emissions
humidity (noncondensing)