15.0 Troubleshooting - Display Messages

There are a number of unique functions designed into your
Sundance hot tub to protect it from damage and/or to aid in
troubleshooting. The indicator light located on the front cabinet
panel of the spa is an early detection system that will notify
you when the spa needs immediate attention. A solid white
light indicates that all operations are normal. A solid red light indicates
that immediate attention is required to clear or fix an error code. Follow-
ing is a listing of all the possible messages along with their meanings.
Always insist on genuine Sundance replacement parts.
Open Flow Switch
The flow switch is malfunctioning open.
Heater is disabled. The circ pump's filter
is dirty, or an air lock has occurred at
the pump intake. Contact your dealer or
service organizations.
1. Open Flow Switch: (Heater is deactivated. The filter/circulation may
also be deactivated.) The flow switch is malfunctioning open, the
circulation pump's filter cartridge is excessively dirty or an air lock
condition has occurred at the circulation pump intake. Contact your
authorized dealer or service organization.
2. Closed Flow Switch: (Heater is deactivated. The filter/circulation
may also be deactivated.) The flow switch is malfunctioning closed.
Contact your authorized dealer or service organization.
3. Shorted Hi-limit Temp Sensor: The hi-limit temperature sensor is
not functional. Heater is disabled. This must be repaired only by a
qualified authorized service organization or service technician.
4. Open Hi-limit Temp Sensor: The hi-limit temperature sensor is not
functional. Heater is disabled. This must be repaired only by a
qualified authorized service organization or service technician.
5. Shorted Water Temp Sensor: The temperature sensor is not
functional. Heater is disabled. This must be repaired only by a
qualified authorized service organization or service technician.
6. Open Water Temp Sensor: The temperature sensor is not functional.
Heater is disabled. This must be repaired only by a qualified
authorized service organization or service technician.
7. Closed Flow Switch on Start-up: Flow switch is non-functional.
Closed or shorted flow switch on system start-up (system disabled).
Contact your authorized dealer or service organization.