Rinnai ES17 Conversion Manual

Gas direct vent wall furnace
Hide thumbs Also See for ES17:
Table of Contents

Advertisement

Available languages

Available languages

for the conversion from
Natural Gas (NG) to Liquid Propane Gas (LPG)
for the conversion from
Liquid Propane Gas (LPG) to Natural Gas (NG)
for adjustments at high altitude
(greater than 2000 ft / 610 m)
WARNING
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes and
requirements of the authority having jurisdiction. If the information in these
instructions is not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this
kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions
supplied with the kit.
Conversion Manual for the
ES17 (RHFE-433RFA)
ES22 (RHFE-558RFA)
Gas Direct Vent Wall Furnace
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or
hurt you and others.
Indicates an imminently hazardous situation which, if not avoided, will result
DANGER
in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result
WARNING
in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result
CAUTION
in minor or moderate injury. It may also be used to alert against unsafe
practices.
Energysaver
®

Safety Symbols

English
Technical Data .......................... 2
Conversion Procedure .............. 3
Parts List ................................... 11
Français
Données Techniques ................ 7
Haute Altitude ........................... 7
de Gas ...................................... 9
Liste des Pièces ........................ 11

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai ES17

  • Page 1: Table Of Contents

    Conversion Manual for the ES17 (RHFE-433RFA) ES22 (RHFE-558RFA) Energysaver ® Gas Direct Vent Wall Furnace English Technical Data ......2 for the conversion from High Altitude ......2 ⇒ Natural Gas (NG) to Liquid Propane Gas (LPG) Conversion Procedure ....3 Adjust Gas Pressure Settings ...
  • Page 2: Technical Data

    For high altitude installations in Canada, the conversion shall be carried out by a manufacturer’s authorized representative, in accordance with the requirements of the manufacturer, provincial or territorial authorities having jurisdiction and in accordance with the requirements of CAN/CGA-B149.1 or CAN/CGA-B149 installation codes. Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 3: Conversion Procedure

    3. Install the manifold (2 screws) and overheat switch bracket (1 screw). Nozzle Manifold 4. Complete the procedure, Adjust Gas Pressure Settings. Overheat Switch (Fig. #3) Nozzle Manifold Burner Injectors (Fig. #4) Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 4: Adjust Gas Pressure Settings

    7. Press the SW1 test button to record the gas type Temp code into memory. The LED will display “F1”. If Control not shown, use the ▲ and ▼ buttons to obtain “F1”. Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 5 • check for gas leaks at the test points Final Assembly 1. Install the front panel and bottom cover. 2. Place the conversion plate (label) on the front cover. Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 6 évitée peut entraîner des blessures graves voire mortelles. Indication d’une situation potentiellement dangereuse, qui si elle n’est pas évitée ATTENTION peut entraîner des blessures légères ou moyennes. On peur également l’utiliser pour signaler des pratiques non sûres. Rinnai Société ES17 / ES22 Manuel de conversion...
  • Page 7: Données Techniques

    Pour des installations d'altitude élevée au Canada, la conversion doit être effectuée en suivant les conditions requises par les autorités des provinces ayant jurisdiction et conformément aux exigences 1 et 2 du Code d’Installation CAN1-B149. Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 8: Procédure De Conversion

    3. Installer le divers (2 vis) et surchauffe le crochet de commutateur (1 vis). (Fig. #3) 4. Compléter la procédure, Ajuster les Cadres de Pression de Gaz. distributeur orifices du br ûleur principal (Fig. #4) Rinnai Société ES17 / ES22 Manuel de conversion...
  • Page 9: Ajustage Et Reglage De La Presion De Gas

    A1: Le gaz naturel en-dessous 2000 ft (610 m) RoomTemp A2: Le gaz naturel 2001-5200 ft (611-1585 m) Temp La température A3: Le gaz naturel 5201-7700 ft (1586-2347 m) Control commande A4: Le gaz naturel 7701-10200 ft (2348-3109 m) Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 10 2. Placer la plaque de conversion (l'étiquette) sur la • visuellement inspecter la flamme couverture de devant. • le contrôle pour gaze des fuites aux points de test Rinnai Société ES17 / ES22 Manuel de conversion...
  • Page 11: Parts List

    Liste des Pièces (du gaz naturel au gaz propane) Quantity Part Name Part No. Visual Reference (Nom de la Pièce) (Numero de pièce) (Gaz) (Référence visuelle) Quantité AU129-210-0.85 Injector (Injecteur) 0.033 in (0.85mm) Conversion Plate CP-72317-16 (Plaque de Conversion) Rinnai Corporation ES17 / ES22 Conversion Manual...
  • Page 12 • Up to 83% AFUE Energy Efficiency • Zero-Clearance Installation • Available in Four Options of Fronts • Remotes and Fan Included • Gas Conversion Kit Available Hydronic Air Handler Designed for Use with Rinnai Systems • Domestic Hot Water Priority • Optional Programmable Thermostat •...

This manual is also suitable for:

Es22