Shelf Voltage And Temperature; Cooling Profile - Cisco NCS 2006 Hardware Installation Manual

Ncs 2000 series
Table of Contents

Advertisement

Shelf Voltage and Temperature

b Plug the other end into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
2 Using a cross-over (CAT-5) LAN cable:
a Plug one connector into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
b Plug the other end into the P-MSM-1 port of the NCS 2015 SSC 2 that corresponds to the control card
3 Using a cross-over (CAT-5) LAN cable:
a Plug one connector into the M-MSM-1 port of the NCS 2015 SSC 2 that corresponds to the control
b Plug the other end into the RJ-45 port of the control card in Slot 7 of ONS 15454 SSC 3.
4 Repeat Steps 2 and 3 to connect the remaining SSCs.
5 To complete the ring, plug one connector of a cross-over (CAT-5) LAN cable into P-MSM-1 port of NCS
2015 SSC 15. Plug the other connector into the RJ-45 port of the control card in Slot 11 of ONS 15454
NC.
Shelf Voltage and Temperature
The temperature that the TNC, TNCE, TSC, or TSCE sensors measure appear on the LCD screen in the
Note
NCS 2006 chassis.
The input voltages and temperature of the NCS 2006 chassis are displayed in the Shelf view > Provisioning
> General > Voltage/Temperature pane in CTC. The voltage supplied to the shelf (in millivolts) is displayed
in the Voltage area of the Voltage/Temperature pane. The temperature of the shelf (in degree Celsius) is
displayed in the Temperature area of the pane.
The Voltage/Temperature pane retrieves the following values for the NCS 2006 chassis:
• Voltage A—Voltage of the shelf that corresponds to power supply A, in millivolts.
• Voltage B—Voltage of the shelf that corresponds to power supply B, in millivolts.
• Chassis Temperature—Temperature of the shelf, in degrees Celsius.
In a multishelf configuration, the voltage and temperature of each shelf is displayed in the Shelf view >
Provisioning > General > Voltage/Temperature pane.

Cooling Profile

The cooling profile feature allows you to control the speed of the fans in the NCS 2006 shelf depending on
the I/O cards used.
Cisco NCS 2000 Series Hardware Installation Guide
438
Slot 1.
Slot 8.
in Slot 17.
card in Slot 1.