Mitsubishi FREQROL-SFJ Maintenance Manual page 109

Ac spindle drive
Table of Contents

Advertisement

Cause
Encoder type oriented
spindle stop function
adjusted improperly
Sync. TAP adjusted
improperly
Trouble with encoder
Trouble with card
SF-ORJ, TLJ or DAJ
Checkup
Check if alarm is removed
when value of parameter
CSP setting is halved.
Check if alarm is removed
when sync. TAP command
time constant is increas-
ed.'
Stop position is valiable
in each oriented spindle
stop (encoder type).
(Check the encoder shaft.)
Check if alarm is removed
when card SF-ORJ, TLJ, or
DAJ is replaced with a new
one.
Remedy
Set parameter
OSP properly.
Set time constant
Replace the en-
coder.
Replace card SF-
ORJ, TLJ or DAJ.

Hide quick links:

Advertisement

Table of Contents
loading