Installing FRUs

WARNING!
Long-time exposure to strong air flow might cause discomfort. To avoid this hazard, Hewlett Packard
Enterprise recommends not standing close to the air outlet vents while the switch is operating. If you
must be next to the switch on the air outlet vent side for an extended period, avoid the air flow or take
other protective measures.
CAUTION:
• Install filler panels in empty chassis slots to ensure ventilation in the chassis.
• Hewlett Packard Enterprise recommends that you connect power cords after installing all
required FRUs.
TIP:
Keep the chassis and the component packages for future use.
Attaching an ESD wrist strap
The switch provides an ESD wrist strap. To minimize ESD damage to electronic components, wear
the ESD wrist strap and make sure it is reliably grounded before you install FRUs.
To attach an ESD wrist strap:
Make sure the switch is reliably grounded. For information about how to ground your switch,
1.
see
"Installing the
Put on the wrist strap.
2.
Tighten the wrist strap to make sure it makes good skin contact. Make sure the resistance
3.
reading between your body and the ground is between 1 and 10 megohms.
As shown in
4.
switch."
Figure
17, insert the ESD wrist strap into the ESD jack on the chassis.