Technical Data - Siemens SINUMERIK 840D sl Manual

Sinumerik 840d sl type 1b ncu 7x0.3 pn, ncu 7x0.3b pn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Bit
1
0
Note
The "alive and well" counter is a 3 bit modulo counter at the PP application level. The PP
application can be monitored using this counter. Failure of the application software does not
generally result in a communication failure, as this is developed in a hardware-supported
manner. The watch dog switches off the digital outputs, while the inputs remain at their last
set values.
Table 9-30
"alive and
well" counter
0
1
2
3 ... 7
9.2.5

Technical data

Table 9-31
Safety
Degree of protection
Protection class
Approvals
Power consumption at rated load (without digital outputs)
PP 72/48D PN
PP 72/48D 2/2A PN
Mechanical data
Dimensions WxHxD
Weight, approx.
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Signal name
Message
Diag_1
Overload DO byte 3/2
Diag_0
Overload DO byte 1/0
Messages in byte 1, depending on the "alive and well" counter
Value
Message
byte 1
0
Reserved
Temperature value
5
Internal error, system error
Effect: The "PNFault" LED is activated. The outputs are disabled. The value
0x80 is stored in status byte 1.
Remedy: Switch the module off and on again.
0
Reserved
Technical data of the I/O module
IP 00 according to EN 60529
III; DVC A, (PELV) acc. to EN 61800-5-1
cULus, CE
17 W
19 W
150 x 300 x 35 mm
0.9 kg
Connectable components
9.2 PP 72/48D PN