Figure 10
Fresh Water (Coolant) Level Indicator and
Alarm (Figure 10) - When the amount of
cooling water in the fresh water recovery
tank falls below normal, the sensor will send
a signal to the indicator causing it to light and
the alarm to sound. Stop operation
immediately to avoid damage to the engine.
Check the water level in the cooling water
recovery tank and troubleshoot the cooling
system.
Figure 11
Fuel Filter (Water Separator) (Figure 11) -
When the water level inside the water
separator becomes too high, the sensor will
send a signal to the indicator causing it to
light. Drain the water separator. If operation
is continued without draining the water
separator, fuel feed to the engine is
restricted and may cause damage to the
engine or fuel injection pump.
6LPA Series Operation Manual
0004882
© 2007 Yanmar Marine International
PRODUCT OVERVIEW
Figure 12
Exhaust (Cooling Seawater Flow)
Restriction (Figure 12) - When the amount
of cooling seawater being discharged is too
low, the sensor will activate the warning
indicator. Stop operation immediately to
avoid damage to the engine. Check the
seawater cooling system for restriction or
damage.
Figure 13
Gear Oil Level (6LPA-STZP2 Only)
(Figure 13) - When the amount of gear oil
falls below normal, the sensor will send a
signal to the indicator causing it to light and
the alarm to sound. Stop engine
immediately to avoid damage to the gear
device. Check the oil level in the gear and
troubleshoot the gear system.