Summary of Contents for Comelit 2708W

  • Page 1 TECHNICAL MANUAL Door-entry phone Art. 2708W...
  • Page 2: Table Of Contents

    Warning Intended use This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
  • Page 3: Description

    Description Art. 2708W is a door-entry phone complete with 1 key button, 1 P1 button and a 3-position ringtone / Privacy service selector, which can be used in SB1 systems. Dimensions 105×190×28 mm. 1. Loudspeaker. 7. Terminal block M1: CFP CFP floor door call input 2 Audio hook.
  • Page 4: Technical Characteristics

    Technical characteristics MAIN SPECIFICATIONS System SimplebusTop ( S1 ) Audio system Yes Audio/video system No Wall-mounted Yes Desk base-mounted Yes Hands-free function - Induction loop function - Product color White Total buttons 2 LED signaling No FUNCTIONS Actuator control function Yes Switchboard call function Yes Panic call - General intercom call -...
  • Page 5: Installation

    Installation mm 105 max 7cm CLACK! CLACK!
  • Page 6: Connections

    Connections Connection to the door entry riser and the floor door call button 2708W 1622 Where multiple door-entry phones or monitor backplates have the same user code, connect the CFP button on one only; all the devices will ring simultaneously.
  • Page 7: Dip Switch Programming Table

    Dip switch programming table Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Code Code Code Code Code Code Code Code 1,2,3,4,5 1,3,4,5,6 1,2,4,5,7 1,4,5,6,7 1,2,3,5,8 1,3,5,6,8 1,2,5,7,8 2,3,4,5,6 3,4,5,7 2,4,5,6,7 4,5,8 2,3,5,6,8 3,5,7,8 1,2,3,4,5,6 1,3,4,5,7...
  • Page 8: Operating Distances

    Operating distances 2708W 2708W (MAX 4) 1622 1595 A MAX B MAX 1 mm² (Ø 1,2 mm AWG 17) 50 m 500 m (165 feet) (1625 feet) 0,28 mm² (Ø 0,6 mm AWG 23) 300 m (15 feet) (990 feet) 0,5 mm²...
  • Page 9: Wiring Diagram

    Wiring diagram Door-entry phone system for one entrance with audio external unit. Switching on/voltage check with system in standby. 23-27 Vdc 2708W 23-27 Vdc 2708W 1595 33 Vdc 120-230 V 27 Vdc 1622 33436 33 Vdc Local lock-release button. SBC/01M...