Bosch Solution 3000 Quick Reference Manual page 29

Hide thumbs Also See for Solution 3000:
Table of Contents

Advertisement

Control Panel
Item
Zone Pulse Count
Zone Pulse Count Time 0353
Zone Options 1
Zone Options 2
Reserved
Zone Report Options
Zone #15
Zone Type
Zone Pulse Count
Zone Pulse Count Time 0367
Zone Options 1
Zone Options 2
Reserved
Zone Report Options
For zone item options, refer to below Zone Item Options.
Item
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Bosch Security Systems, Inc.
Location Default
New
0352
0
0
0354
1
0355
14
0356
0357
1
0365
15
0366
0
0
0368
1
0369
14
0370
0371
1
Option
0 = Instant
1 = Handover
2 = Delay-1
3 = Delay-2
4 = Reserved
5 = Reserved
6 = 24-Hour Medical
7 = 24-Hour Panic
Use the pulse count to program how many pulses (0 to 15) need to
be registered within the pulse count time to activate an alarm.
20 ms Loop Response Time
0 = 0.5 sec.
1 = 1 sec.
2 = 2 sec.
3 = 3 sec.
4 = 4 sec.
5 = 5 sec.
6 = 10 sec.
7 = 15 sec.
Item
Zone Pulse Count
Zone Pulse Count Time 0360
Zone Options 1
Zone Options 2
Reserved
Zone Report Options
Zone #16
Zone Type
Zone Pulse Count
Zone Pulse Count Time 0374
Zone Options 1
Zone Options 2
Reserved
Zone Report Options
8 = 24-Hour Hold-up
9 = 24-Hour Tamper
10 = Reserved
11 = Keyswitch
12 = 24-Hour Burglary
13 = 24-Hour Fire
14 = Chime Only
15 = Not used
150 ms Loop Response Time
8 = 20 sec.
9 = 30 sec.
10 = 40 sec.
11 = 50 sec.
12 = 60 sec.
13 = 90 sec.
14 = 120 sec.
15 = 200 sec.
Quick Reference Guide
Programming Parameters | en
Location Default
New
0359
0
0
0361
1
0362
14
0363
0364
1
0372
15
0373
0
0
0375
1
0376
14
0377
0378
1
2015.06 | 03 | F.01U.298.027
29