Identifying A Css Component - Fujitsu PRIMERGY TX200 S5 Operating Manual

Hide thumbs Also See for PRIMERGY TX200 S5:
Table of Contents

Advertisement

Replacement of non-hot-plug components
Figure 29: Example: Removing system fan 1&3
Ê Disconnect the fan cable from the connector FAN1 on the system board (if
there is a second fan cable, disconnect this from FAN3).
Ê Push the locking lever in the direction of the arrow (1).
Ê Pull system fan 1 (and 3) in the direction of the arrow (2) to disengage the
four hooks.
Ê Take system fan 1 (and 3) out (3).
8.2.1.4

Identifying a CSS component

Ê Press the Indicate CSS button on the system board (see the technical
manual for the system board D2709 on the PRIMERGY ServerView Suite
DVD 2).
The PRIMERGY Diagnostic LED of the defective CSS component lights up
orange, thereby indicating which CSS component (memory module, fan or
expansion card) on the system board must be replaced (see technical
manual for the system board D2709).
100
Operating Manual
CSS components
TX200 S5