Bit and DM Area Allocations
Processing Data
IR Area Contents: Outputs
Address
Word
Bit
(IR)
n
15 to 08
---
07 to 00
Peak Value ON Bits
IR Area Contents: Inputs
Word
Bit
(IR)
n+1
15 to 00
Input 1 A/D conversion data
or processing data
n+2
15 to 00
Input 2 A/D conversion data
or processing data
n+3
15 to 00
Input 3 A/D conversion data
or processing data
n+4
15 to 00
Input 4 A/D conversion data
or processing data
n+5
15 to 00
Input 5 A/D conversion data
or processing data
n+6
15 to 00
Input 6 A/D conversion data
or processing data
n+7
15 to 00
Input 7 A/D conversion data
or processing data
n+8
15 to 00
Input 8 A/D conversion data
or processing data
n+9
15 to 08
Limit warning
07 to 00
Disconnection detection
DM Allocations
DM
word
d
15
14
m
0
m+1
Input signal range (00 specifies –10 to +10 V, 01 specifies 0 to 10 V, and 10 specifies 1 to 5 V/4 to 20 mA.)
Input 8
m+2
Input 8
Input 7
Input 6
m+3
Input 8
Input 7
Input 6
16
Note When the input range is set to –10 V to +10 V, the 15
status of 0 indicates "+" and a bit status of 1 indicates "–." There is no sign bit
when the scaling or square root function is being executed.
When scaling, mean value processing, peak value, or square root calculation is
executed, the resulting data is output.
Note When scaling is executed, it is set in IR words n+1 through n+8 in BCD.
Item
Not used. Set these bits to 00 (OFF).
Turn these bits to 1 (ON) to execute the peak value function for the
corresponding input. Bits 00 through 07 correspond to inputs 1
through 8.
Refer to 2-3-7 Peak Value Function for more details.
Item
The A/D conversion data is set here for each input.
The conversion data range is as follows when the input signal range
The conversion data range is as follows when the in ut signal range
is set to 0 to 10 V, 1 to 5 V, or 4 to 20 mA:
The conversion data range is as follows when the input signal range
is set to –10 to 10 V:
i
When the input range is set to –10 V to +10 V, the 15
the sign A bit status of 0 indicates "+" and a bit status of 1 indicates
the sign. A bit status of 0 indicates "+" and a bit status of 1 indicates
"–." (There is no sign bit when the scaling or square root function is
being executed.)
being executed.)
The processing results for the scaling, mean value, peak value, and
square root functions are output here when those functions are being
square root functions are out ut here when those functions are being
executed.
When the limit warning has been set, these bits are turned ON to
indicate that the corresponding input's value has exceeded the
range. Bits 08 through 15 correspond to inputs 1 through 8.
These bits are turned ON to indicate that a disconnection or broken
wire has occurred in the corresponding input. Bits 00 through 07
correspond to inputs 1 through 8.
Unit numbers 0 to 9:
Unit numbers 10 to 15: n = 400 + 10 x (unit number – 10)
13
12
11
10
0
0
Input 7
Input 6
Scaling execution
Input 5
Input 4
Input 3
Square root execution
Input 5
Input 4
Input 3
BCD data:
0000 to 4000
Binary data:
Bi
d
0000
0000 to 0FA0
g
V
BCD data:
A000 to 8001, 0000 to 2000
Binary data:
Binary data:
87D0 to 8001 0000 to 07D0
87D0 to 8001, 0000 to 07D0
n = 100 + 10 x unit number
Bit
09
08
07
06
Limit
Data
warning
warning
type
type
mode
setting
Input 8
Input 7
Input 5
Input 4
Input 2
Input 1
Input 8
Input 7
Input 2
Input 1
Input 8
Input 7
Section 2-2
th
bit indicates the sign. A bit
Contents
Contents
0FA0
th
bit indicates
05
04
03
02
Conversion prohibit setting
Input 6
Input 5
Input 4
Input 3
Input 3
Input 2
Mean value execution
Input 6
Input 5
Input 4
Input 3
Limit warning execution
Input 6
Input 5
Input 4
Input 3
g
g
01
00
Input 2
Input 1
Input 1
Input 2
Input 1
Input 2
Input 1