Attaching ground wires for unused ground blocks
Procedure
1. Attach the Supplementary Ground Conductor to an approved ground.
2. Connect the AC power cable to the inlet receptacle on the rear of the chassis.
Result
Note:
If two PSUs are installed in the Branch Gateway, the PWR LED blinks if only one PSU is
connected to power, and stays on if both PSUs are connected to power.
Related links
Attaching the ground wires

Connecting power to the EM200 expansion modules

About this task
Warning:
Connect power to the EM200 expansion modules before you connect power to the G430.
Failure to do so may cause unexpected results.
For each EM200 module you connected to the G430:
Procedure
1. Connect the power cable to the power connector on the EM200 back panel.
2. Plug the power cable into a mains socket.
The EM200 is now powered.
The V5-V6 LED on the EM200 front panel lights if the EM200 is connected to the
CONNECTOR OUT 1 connector on the rear panel of the G430. This indicates that the two
media module slots are considered slot 5 and slot 6 of the G430.
The V7-V8 LED on the EM200 front panel lights if the EM200 is connected to the
CONNECTOR OUT 2 connector on the rear panel of the G430. This indicates that the two
media module slots are considered slot 7 and slot 8 of the G430.
The PWR LED on the front panel lights, indicating the EM200 is powered.
Result
Warning:
If you wish to move an EM200 in a working system consisting of a G430 and one or two
EM200s housing media modules, you must disconnect the EM200 from power before
reconnecting the expansion cable to the new location. Failure to do so may cause unexpected
results.
February 2017
on page 40
Installation and Upgrades for the Avaya Branch Gateway G430
Comments on this document? infodev@avaya.com
Ground conductor attachments
41