Viessmann VITODENS 200-W Installation And Service Instructions Manual page 82

Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault code
Const.
displayed
E2
X
E3
X
E4
X
E5
X
E6
X
E7
X
E8
X
82
Weather-
System characteris-
comp.
tics
X
Burner in a fault state Heating water flow
X
Burner in a fault state Heat transfer too
X
Burner blocked
X
Burner blocked
X
Burner blocked
X
Burner in a fault state Ionisation current
X
Burner in a fault state Ionisation current
Cause
Measures
Ensure adequate circula-
rate too low during
tion volume.
calibration. Flow
Check flow switch.
switch has shut
Remove scaling and
down.
blockages.
Press reset button R.
Ensure adequate heat
low during calibra-
transfer.
tion
Press reset button R.
Temperature limiter
has shut down.
Fault, 24 V supply
Replace control unit.
voltage
Flame amplifier
Replace control unit.
fault
System pressure
Top up with water.
too low
Check ionisation elec-
too low during cali-
trode:
bration
Distance to burner
gauze assembly (see
page 36)
Electrode contamination
Connecting lead and
plug-in connections
Check flue system; reme-
dy flue gas recirculation if
required.
Press reset button R.
Check gas supply (gas
lies outside the
pressure and gas flow
permissible range
switch), gas train and
connection pipe.
Check assignment of gas
type (see page 30).
Check ionisation elec-
trode:
Distance to burner
gauze assembly (see
page 36)
Electrode contamination
Press reset button R.