Diagnosis and service scans
Diagnosis
(cont.)
For an explanation of the relevant values in the individual rows and fields, see the following table:
Row (brief
scan)
1
1:
System scheme 01 to 10
2:
0
3:
0
4:
Software version
Burner control unit
5:
Internal details for calibration
6:
0
7:
LON
Subnet address/system num-
ber
8:
LON
SBVT config-
uration
9:
Heating circuit A1 (without
mixer)
Remote con-
trol
0: Without
1: Vitotrol
200A/
200 RF
2: Vitotrol
300A/
300 RF
or
Vitocomfort
10:
0
11:
0
Constant temperature control unit
1. Press OK and
simultaneously for approx. 4 s.
å
"
" flashes on the display.
Ü
2. Confirm with OK.
72
2
3
Software version
Control unit
0
Appliance version
Number of KM BUS subscrib-
ers
Type
Burner control unit
0
0
LON
Node address
LON
LON
Software ver-
Software version, neuron chip
sion, commu-
nication cop-
rocessor
Heating circuit M2 (with
mixer)
Software ver-
Remote con-
sion, remote
trol
control
0: Without
1: Vitotrol
200A/
200 RF
2: Vitotrol
300A/
300 RF
or
Vitocomfort
0
0
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M2
0: No mixer
extension
3. Select the required scan with
4. Confirm selected scan with OK.
Field
4
5
Software version
Programming unit
Appliance ID CU-ID
Software version, solar control
module SM1
Burner control unit version
0
Software ver-
sion, AM1 ex-
tension
Flow sensor
0
switching
state
1: Flow rate
too low or not
present
0
Number of LON subscribers
Heating circuit M3 (with mix-
er)
Software ver-
Remote con-
sion, remote
trol
control
0: Without
1: Vitotrol
200A/
200 RF
2: Vitotrol
300A/
300 RF
or
Vitocomfort
0
0
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M3
0: No mixer
extension
"b" for "Max. output" (see following table):