Panasonic DMR-EH59GC Service Manual page 27

Table of Contents

Advertisement

Mode Name
HDD READ VERIFY
Measure of access time in READ VERIFY
Inspection
MODE of HDD.
HDD Spin-up time
The accumulation value of the Spin-up time of
HDD is displayed.
Item
Description
FL Display
At start
The [*] sign is added every 20
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position at $ is space when
excluding those.
##: Number of data of over
100msec. and less than 270msec.
When it is over 100, [99] is
displayed.
When the number is less than 5, we
judge it normal.
Spin-up time of HDD is displayed.
(The unit of display is hour.)
27
Key Operation
(Remote controller key)
Press [3] [2] in service mode.
* When canceling the inspection
mode while executing, do "forced
power-off".
Method: Press [POWER] key more
than 10 seconds.
Press [3] [3] in service mode.