Installation
Guide
Shaded areas below apply _
to TH6220D:
t HIt
C System
(1 transformer)
s w c ¥ R Ro
CRRC
Power
[11
[R+Ro joined
by jumper]
Y
Compressor
oontaotor
C
24VAC common
[3]
W
Heat
relay
G
Fan relay
Heat-only
System
CRc
Power [1]
w c
R Sc
R
[R+Ro joined
by jumper]
C
24VAC common
[3]
W
Heat
relay
Heat-only
System
(Series 20)[5]
w c Y R Rc
RC
[R+Ro joined
by jumper]
C R
Series
20 valve terminal
"R" [1]
Y
Series
20 valve terminal
"W"
C
24VAC common
[3]
W
Series
20 valve terminal
"B"
Heat-only
System
(normally
open zone
valve) [5]
c Y s R¢
C RRc
[a+Rs
joined
by jumper]
Power
[1]
Y
Normally
open
zone valve
C
24VAC common
[3]
t HI1 C System
(2 transformers)
G W C ¥ R Re
Rc
Power
(cooling
transformer)
[1, 2]
R
Power (heating
transformer)
[1, 2]
Y
Compressor
oontaotor
C
24VAC common
[3, 4]
W
Heat
relay
G
Fan relay
Heat-only
System
with
Fan
G W C
S Ro
Powor Ell
[R+Ro joined
by jumper]
C
24VAC common
[3]
W
Heat relay
G
Fan relay
Cool-only
System
C FIc
Power
[1]
G
c Y s so
R
[R+Ro joined
by jumper]
Y
Compressor
oontaotor
C
24VAC common
[3]
G
Fan relay
2H/2C
System
( I transformer)
[6]
v2 w2 e W C Y R R_
c Rc
Power
[1]
R
[R+Ro
joined
by jumper]
Y
Compressor
oontaotor
(stage 1)
C
24VAC common
[3]
W
Heat
relay (stage
1"_
G
:an
relay
W2
Heat
relay (stage
2}
Y2
Compressor
oontaotor
(stage 2)
2H/20
System
(2 transformers)
[6]
Rc
Power
(cooling transformer)
[1, 2]
R
Power
(heating transformer)
[1,2]
Y
Compressor
oontaotor
(stage 1)
C
24VAC common
[3, 4]
W
Heat
relay (stage
II
G
:an
relay
W2
Heat
relay (stage
2}
Y2
Compressor
oontaotor
(stage
2)
See
[notes]
below
NOTES
Wire specifications:
Use 18- to 22-gauge
thermostat
wire.
Shielded
sable
is not required.
[1]
Power supply.
Provide
dissonnest
means and
overload
protection
as required.
[2]
Remove
jumper
for 2-transformer
systems.
[3]
Optional
24VAC sommon
sonneotion.
[4]
Common
sonnestion
must come from cool-
ing transformer.
[5]
In Installer Setup, set system type to Heat Only.
[6]
In Installer
Setup,
set system type to 2Heat/
2Cool
Conventional.
[7]
In installer Setup,
set changeover
valve to O
or B.
[8]
In Installer
Setup,
set system type to 2Heat/
1Cool
Heat Pump.
[9]
L terminal
sends a continuous
output
when
thermostat
is set to Em. Heat. Connect
to
Honeywell
zoning
panels
to switch
the panel
to Emergency
Heat.
[10]
install field jumper
between
Aux and E if
there
is no emergensy
heat relay.

Advertisement

loading

This manual is also suitable for:

Focuspro th6220d