Fig. 23 - Injector
13.2.

Offset pressure calibration

For the adjustment of the offset pressure, connect a manometer with a resolution of 1 Pa (100 Pa=1 mbar)
to the offset pressure test point after loosening the sealing screw. To adjust the cavity gas valve offset, set
an hot air cycle, half power; to adjust the boiler gas valve offset select a steam cycle, half power. Wait
around 3 minutes for the stabilization of the pressure before adjusting it turning slowly the screw indicated
in the picture above.
13.3.

Use of manometer (for offset pressure measure)

File: AOS service manual (ENG).008
AOS OVENS - Service Manual
(595889300 – ENG)
+
Fig 24 - LPG flange 1/1
©Copyright 2002 by Electrolux Professional
Offset adjustment screw
Offset pressure test point
21
25
Fig. 25 - LPG flange 2/1