Electrolux AOS061E Series Service Manual page 23

Hide thumbs Also See for AOS061E Series:
Table of Contents

Advertisement

Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
Connector
X1
Main board supply (24 Vac)
Power supply to cavity fan motors, cooling fans, cavity flap motor, switching feeder for the
X2/3
lambda probe
Power supply to coils of cavity/boiler heating element contactors or cavity/boiler burner
X4/5
gas valves, steam condensing valve, humidifier valve, cavity lamps
X6/7
Power supply to boiler water filling valves, boiler drain valve
X8
Power supply to cleaning system
X9
Output of PWM signal for burner fans
High voltage digital input, i.e. thermal protection of the cavity fan motors and command
X10/11
signal of the burner fans form the ignition devices
Low voltage digital input, i.e. cleaning system water pressure switch, cavity limiter, boiler
X12/13
limiter, door micro switch and micro switch of the cavity flap
X14
Connection of bypass probe
X15
Connection of cavity probe
X16
Connection of boiler probe
X17
Connection of single point meat probe
X18
Connection of second cavity probe
X19
Connection of second boiler probe
X20, X21, X22
Connections of multi point probe
X23
Connection of lambda probe
X25/26
Connections of water level probes
X28
RS485 connection
File: AOS service manual (ENG).008
AOS OVENS - Service Manual
(595889300 – ENG)
Description
©Copyright 2002 by Electrolux Professional
P.23/40