Name
hboL
Boiler hour counter
HbYP
Max humidity value to stop the boiler
HCCP
HACCP Mode
hcMb
Combi hour counter
hStM
Steam hour counter
HUIM
Pulse length of manual humidifier
HUon
ON phase of the humidifier with combi cycle beetween 50 and 100 degrees
I
Parameter i of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC)
ISG
Define if the oven is an ISG oven (0 means oven with boiler)
LAMb
Presence of lambda probe (1=yes)
LAnG
Language for the menu
MHUM
Flag manual humidifier 0=Off 1=On
MISG
Max temperature allowed for water injection in ISG
nMod
Define if the modification of store program is disable
nPrG
Max number of programs
OCA1
OFFSET of first cavity probe
OCA2
OFFSET of second cavity probe
OLbd
Calibration of the lambda probe
OPr1
OFFSET of first probe of 6-point meat probe
OPr2
OFFSET of second probe of 6-point meat probe
OPr3
OFFSET of third probe of 6-point meat probe
OPr4
OFFSET of fourth probe of 6-point meat probe
OPr5
OFFSET of fifth probe of 6-point meat probe
OPr6
OFFSET of sixth probe of 6-point meat probe
pdEr
Sample period to calculate the derivative value (FUZZY-LOGIC)
PI
Parameter p of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC)
PPM
Flag to enable Peak Power Management (0=disable; 1=enable)
Sbc
Cooling temperature set for board ventilation
SbYP
Bypass temperature with max. cooking cavity steam temperature (calibration)
SEAL
Altitude above sea level
SInC
Boiler temperature that detect presence of scale
SPHb
Preheating temperature of the boiler
SPHF
Boiler temperature during leavening
Stbo
PWM value at start of boiler burners
StbP
Steam condenser engagement in "boiler" mode
StcA
PWM value at start of cavity burners
StoF
Minimum time for "switch off" of boiler
Ston
Minimum time for "switch on" of boiler
tbon
Timeout for E SL alarm, water level probe alarm
tcdb
Max water temperature for boiler drain
thMA
Define the max. temperature limit for the manual injection of water
tPrm
Print frequency (0=no print)
trMA
Define the max. temperature for water injection during cooling phase
trMn
Define the min. temperature for water injection during cooling phase
File: AOS service manual (ENG).008
AOS OVENS - Service Manual
(595889300 – ENG)
Description
©Copyright 2002 by Electrolux Professional
P.31/40