Electrolux AOS061E Series Service Manual page 34

Hide thumbs Also See for AOS061E Series:
Table of Contents

Advertisement

Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
AOS201G
UPPER CAVITY BURNER
LPG2/G30
LOWER CAVITY BURNER
LPG2/G30
BOILER BURNER
LPG conversion for cavity burner for AOS201G
For LPG installations, put the ø 21 flow reducer flange between cavity burner fan and cavity burner. Change
the PWM parameters.
Then change the injector with the 5.70 one and calibrate the offset in the range - 0.15 ÷ - 0.08 hPa so as to
eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down
and verify ignitions with cold burner.
If the previous setting does not eliminate whistles or noise, change the 5.7°0 injector with the 5.50 one and
use the calibrations of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ 0.00 hPa so as to eliminate
possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify
ignitions with cold burner.
File: AOS service manual (ENG).008
GAS
Injector Aerator
G20
7.00
G25
8.00
5.50
LPG1
5.70
GAS
Injector Aerator
G20
7.00
G25
8.00
5.50
LPG1
5.70
GAS
Injector Aerator
G20
8.00
G25
8.50
G30
6.15
LPG
6.15
©Copyright 2002 by Electrolux Professional
AOS OVENS - Service Manual
(595889300 – ENG)
OFFSET
(hPa)
StcA hAcA FucA
Red
- 0.25
80
Red
- 0.25
80
Red
- 0.07÷ 0.00
23
Red
- 0.15÷ - 0.08 23
OFFSET
(hPa)
StcA hAcA FucA
Red
- 0.25
80
Red
- 0.25
80
Red
- 0.07÷ 0.00
23
Red
- 0.15÷ - 0.08 23
OFFSET
(hPa)
Stbo hAbo Fubo
Blue
0
42
Blue
0
42
Blue
- 0.15
30
Blue
0
30
Parameters
26
100
26
100
26
100
26
100
Parameters
26
100
26
100
26
100
26
100
Parameters
45
100
45
100
37
72
37
72
P.34/40