Installation Instructions; Cold Water Connection - GE GXK285JBL Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT –
for local inspector's use.
IMPORTANT –
public works department for plumbing codes. You
must follow their guides as you install the Water
Filtration system.
Note to Installer –
instructions with the Consumer.
Note to Consumer –
for future reference.
• Skill level – Installation of this appliance requires
basic mechanical and electrical skills.
• Completion time – 60-90 minutes
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
WARNING
Information" on page 2 before beginning installation.
TOOLS AND MATERIALS REQUIRED
FOR INSTALLATION
• Phillips screwdriver
• Two (2) adjustable wrenches
• Electric drill and drill bit to drill 1.25" hole (type as
required) if mounting hole is needed for control valve
• Tape measure
• If your main water line is a rigid pipe, you will require
a compression fitting and possibly other plumbing
hardware to complete the installation (sold separately).
To avoid damaging the sink or countertop,
consult a qualified plumber or installer for drilling
procedures. Special drill bits may be needed for granite,
stone, porcelain or stainless steel.
CONTENTS INCLUDED
WITH THE PRODUCT
• Water filter system
assembly, including
mounting screws
• Water line adapters
and tubing
Kitchen Faucet Filtration System –
GXK285JBL
Save these instructions
Check with your local
Be sure to leave these
Keep these instructions
Read "Important Safety
• Control Valve with LED
Lights
• Decorative Knob and Nut
• Timer Box
• Batteries

COLD WATER CONNECTION

A typical connection using the included water
supply fitting is shown in the illustration below.
1. Close the water shut-off valve that is immediately
in front of the supply tube and open the faucets
to drain water from the sink cold water pipe.
2. Remove line that connects the cold water from
faucet line to the supply valve. Some water may
spill out.
1 foot Yellow
3/8" Tube
Angle Stop
Valve Adapter
Existing Cold
Water Valve
(Approximately 8
threads minimum)
T-Fitting
Cold Water Shutoff
3. Hand tighten the angle stop valve adapter onto
the cold water valve. NOTE: A minimum of
approximately 8 threads is required on valve
stem. Finish tightening 1/2 turn with adjustable
wrench. Be careful not to overtighten or cross-
thread as damage to threads can occur.
Some valve threads may be exposed when adapter
is fully seated.
4. Insert one foot long yellow tube fully into angle stop
valve adapter. Pull firmly on tube to make sure it is
secure.
5. Insert one foot long yellow tube into bottom of
T-fitting (see Figure 1). Insert 3 foot long yellow tube
into one side of T-fitting. Insert 4 foot long yellow
tube into other side of T-fitting. Pull firmly on tubes
to make sure they are secure.