■ Check with your local public works department
for plumbing codes. You must follow these guidelines
as you install the Water Filtration system.
■ Use the Water Filtration system on a potable, safe-to-drink,
home COLD water supply only. The filter cartridge
will not purify the water or make it safe to drink.
■ DO NOT use on a hot water supply. Cold water supply only
(40-100° F).
■ Install or store where it will not be exposed to temperatures
below freezing or exposed to any type of weather. Water
freezing in the system will damage it.
■ Your Water Filtration system will withstand up to 125 pounds
per square inch (psi) water pressure. If your house water
supply pressure is higher than 100 psi, install a pressure
reducing valve before installing the Water Filtration system.
REQUIRED TOOLS FOR INSTALLATION
■ Phillips screwdrivers
■ Pliers
■ Adjustable wrench
REQUIRED PARTS FOR INSTALLATION
3/8" Tubing (Pex or Plastic)
2-3/8" NPT Fittings
Teflon Tape
®
2-3/8" Nuts
2 Tube Inserts
Sump Wrench - UCWRNCH
This GX1S01R is Tested and
Certified by NSF international
against NSF/ANSI Standard 42
for materials and structural
C
US
integrity requirements and
COMPONENT
against CSA B483.1.

SAFETY PRECAUTIONS

49-50247-1
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
Water Filtration System
GX1S01R
WARNING:
is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.
Discard all unused and packaging material after installation.
Small parts remaining after installation could be a choke hazard.
OPTIONAL KITS AND TOOLS FOR INSTALLATION
NOTE: Sump wrench (UCWRNCH) and faucet (UNFCTBL)
are sold separately for model GX1S01R.
■ Drill and 1/4" bit (saddle valve installation)
■ Drill and drill bit for 3/4" hole (type as required)
if mounting hole is needed for faucet
■ Pipe cutter
■ File
CAUTION:
To avoid damaging the sink, consult a
qualified plumber or installer for drilling procedures. Special
drill bits may be needed for porcelain or stainless steel.
JR 10-08
1
Do not use with water that

Advertisement

Table of Contents
loading

Summary of Contents for GE GX1S01R

  • Page 1: Safety Precautions

    Installation Instructions ■ Check with your local public works department for plumbing codes. You must follow these guidelines as you install the Water Filtration system. ■ Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter cartridge will not purify the water or make it safe to drink.
  • Page 2: Installation Options

    CAUTION: For connection to cold water line only. Option 1: For connection to primary sink faucet NOTE: For use with filter element FXUTC ONLY. Use of other filter elements could adversely affect main faucet flow rate. 1. Shut off cold water supply. 2.
  • Page 3: Filter Cartridge Installation Or Replacement

    FLUSH PROCEDURE The procedure for flushing the GE Water Filtration system is: See Filter Cartridge Installation or Replacement section and follow steps 1, 2, 3 and 4. Next, reinstall the sump (without the filter element), turn water on and flush water through the faucet.
  • Page 4: Limited One-Year Warranty

    — Defects that result from improper installation or damage not caused by GE. — Liability on the part of GE under this or any other warranty for any indirect or consequential damage. — Products that are used for commercial or industrial applications.
  • Page 5: Système De Filtration D'eau

    Consignes d’installation ■ Consulter le service municipal de distribution d’eau au sujet des codes de plomberie applicables. L’installation du système de filtration d’eau doit être conforme aux prescriptions du code. ■ Utiliser le système de filtration d’eau uniquement sur une canalisation d’eau potable FROIDE.
  • Page 6 MISE EN GARDE : Installer ce produit uniquement sur une canalisation d’eau froide. Option 1: Raccordement sur canalisation du robinet principal de l’évier NOTE : Pour utilisation UNIQUEMENT avec l’élément de filtration FXUTC. L’emploi d’un autre élément de filtration pourrait réduire le débit du robinet principal. 1.
  • Page 7: Méthode De Purge

    Chaque fois que le système de filtration GE est exposé à de l’eau de qualité inconnue, on devrait jeter les éléments de filtration et rincer le circuit. Circonstances qui peuvent nécessiter un rinçage du circuit : ■ Notification de la nécessité de faire bouillir l’eau.
  • Page 8: Liste Des Composants

    — Défauts entraînés par une installation incorrecte ou tout dommage non imputable à GE. — Responsabilité de GE couvert par cette garantie ou toute autre garantie couvrant tout dommage indirect. — Produits utilisés pour des applications industrielles ou commerciales.
  • Page 9: Instrucciones De Instalación

    Instrucciones de instalación PRECAUCIONES DE SEGURIDAD ■ Consulte con su departamento de obras públicas local para los códigos de plomería. Usted debe seguir estas reglas a medida que instala el sistema de Filtración de Agua. ■ Use el sistema de Filtración de Agua solamente en una línea de agua FRIA de hogar que sea potable, segura para ser bebida.
  • Page 10: Opciones De Instalacion

    PRECAUCION: Para conexión a linea de agua fria solamente. Opción 1: Para conexión a la llave primaria de la llave del lavaplatos. NOTA: Para uso con el elemento de filtro FXUTC SOLAMENTE. El uso de otros elementos podrían afectar adversamente el valor del paso de la llave principal.
  • Page 11: Procedimiento De Lavado

    Cada vez que agua de calidad desconocida pasa a través del sistema de Filtración de Agua GE, el elemento del filtro debería ser deshechado y el sistema de filtración lavado. Circunstancias que podrían requerir el lavado del sistema son: ■ Una advertencia de que hay que hervir el agua.
  • Page 12: Lista De Partes

    — Defectos que resulten de una instalación inadecuada o daños no causados por GE. — Responsabilidad de parte de GE bajo esta o cualquier otra garantía por cualquier daño indirecto o por consecuencia de otro evento. — Productos que son usados con fines comerciales o industriales.

Table of Contents