Datalogic PD9330 Quick Reference Manual
Datalogic PD9330 Quick Reference Manual

Datalogic PD9330 Quick Reference Manual

Industrial corded handheld laser bar code reader
Hide thumbs Also See for PD9330:

Advertisement

PowerScan™ PD9330
Industrial Corded Handheld
Laser Bar Code Reader
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PD9330

  • Page 1 PowerScan™ PD9330 Industrial Corded Handheld Laser Bar Code Reader Quick Reference Guide...
  • Page 2 Datalogic has taken reasonable measures to provide informa- tion in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
  • Page 3: Table Of Contents

    Customers Under Software Support .........vii Description ..................1 General Features ..............1 Setting Up the Reader ..............2 Connecting the Cable ............3 Using the PowerScan™ PD9330 ..........4 Scan Line Position ............4 Reading Angle ............. 5 Selecting the Interface Type ............6 Interface Selection ............... 6 Configuring the Interface ...........
  • Page 4 NOTES PowerScan™ PD9330...
  • Page 5: End User Software License Agreement (Eula)

    2. Scope Of License Granted 2.1 Datalogic grants to End User a personal non-exclusive, non-transferable, per- petual license to use the Software, solely on the Datalogic Product in which it is embedded ("designated Datalogic Product"), in machine-readable form only, solely for End User's internal business purposes. This Agreement does not convey ownership of the Software to End User.
  • Page 6: Limited Warranty

    3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or other- wise transfer the Datalogic Product to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions of this Agreement. Any such transfer of the Datalogic Product absent such agreement shall be null and void.
  • Page 7: Limitation Of Liability

    52.227-19 or in the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable. 9.2 If End User is using the Datalogic Product outside of the United States, End User must comply with the applicable local laws of the country in which the Datalogic Product is used, with U.S.
  • Page 8 11.2 Notice. All notices required or authorized under this Agreement shall be given in writing, and shall be effective when received, with evidence of receipt. Notices to Datalogic shall be sent to the attention of Datalogic IP Tech S.r.l., Legal & IP Department, Via San Vitalino 13, 40012 Calderara di Reno (Bologna), Italy or such other address as may be specified by Datalogic in writing.
  • Page 9: Software Product Policy

    Software Product Policy Software Product Policy Datalogic reserves the right to ship its products with the latest version of software/firmware available. This pro- vides our customers with the very latest in Datalogic soft- ware technology. The only exception to this policy is when the buyer has a...
  • Page 10 Software Product Policy NOTES viii PowerScan™ PD9330...
  • Page 11: Description

    To read a symbol, you simply aim the reader Operating by a partial trigger press and pull the trigger. Thanks to powerful algorithms, PowerScan™ PD9330 reliably decodes all major 1D (linear) barcodes. The data stream — acquired from Decoding decoding a symbol — is rapidly sent to the host.
  • Page 12: Setting Up The Reader

    16 (optional, depends on settings needed) Connect the PowerScan by plugging directly into the host device as shown. The power can also be supplied through an external power supply via the Interface Cable supplied with a power jack. PowerScan™ PD9330...
  • Page 13: Connecting The Cable

    Setting Up the Reader Connecting the Cable A. Rubber gasket B. Cable Holder C. Cover D. Connector Holder Slip the cable through the Cover. Push the Rubber Gas- ket onto the Cable FRONT>> Holder. Push the Cable Holder and gasket into the handle.
  • Page 14: Using The Powerscan™ Pd9330

    Using the PowerScan™ PD9330 Using the PowerScan™ PD9330 The PowerScan™ PD9330 normally functions by capturing and decoding bar codes. The reader is equipped with an aiming system which helps to aim the target. Table 1. Aiming System PowerScan™ PD9330 provides an aiming system. If...
  • Page 15: Reading Angle

    If the entire bar code is within the scan line, you will get a good read. Successful reading is signaled by an audible tone plus a good-read green spot LED indicator. Reference the PowerScan PD9330 Product Reference Guide (PRG) for more information about this feature and other programmable settings.
  • Page 16: Selecting The Interface Type

    Information and programming options for each interface type are provided in this section. For defaults and addi- tional information associated with each interface, proceed to the corresponding chapter in the PowerScan PD9330 PRG. Configuring the Interface Scan the appropriate programming bar code to selects the interface type for your system.
  • Page 17 Selecting the Interface Type RS-232 RS-232 standard interface RS-232 RS-232 Wincor-Nixdorf RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS RS-232 OPOS USB Com to simulate RS-232 standard interface USB-COM Quick Reference Guide...
  • Page 18 Selecting the Interface Type USB (continued) USB-OEM (can be used for OPOS/UPOS/JavaPOS) USB-OEM a. Download the correct USB Com driver from www.datalogic.com USB Keyboard with standard key encoding USB-KBD USB Keyboard with alternate key encoding USB-KBD-ALT PowerScan™ PD9330...
  • Page 19: Keyboard Interface

    Selecting the Interface Type Keyboard Interface KEYBOARD WEDGE IBM AT or PS/2 PCs Standard Key Encoding KBD-AT IBM AT or PS/2 PCs Standard Key Encoding without external keyboard KBD-AT-NK IBM AT or PS/2 PCs w/Alternate Key KBD-AT-ALT IBM AT or PS/2 PCs Alternate Key Encoding without external keyboard KBD-AT-ALT-NK Quick Reference Guide...
  • Page 20: Country Mode

    Selecting the Interface Type Country Mode This feature specifies the country/language supported by the keyboard. COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Country Mode = Croatia PowerScan™ PD9330...
  • Page 21 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Czech Country Mode = Denmark Country Mode = France Country Mode = French Canadian Country Mode = Germany Country Mode = Hungary Quick Reference Guide...
  • Page 22 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Italy Country Mode = Japanese 106-key Country Mode = Lithuanian Country Mode = Norway Country Mode = Poland Country Mode = Portugal PowerScan™ PD9330...
  • Page 23 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Romania Country Mode = Spain Country Mode = Sweden Country Mode = Slovakia Country Mode = Switzerland Quick Reference Guide...
  • Page 24: Caps Lock State

    This does not apply when an alternate key encoding key- board is selected. It does not apply to USB keyboard. ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable PowerScan™ PD9330...
  • Page 25: Numlock

    Interfaces section, select other options and cus- tomize your reader through use of the programming bar codes available in the PowerScan PD9330. Check the cor- responding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
  • Page 26: Configure Other Settings

    Factory defaults are based on the interface type. Be sure your reader is configured for the correct interface before scanning this label. See "Selecting the Interface Type" on page 6 for more information. NOTE Reset Default Settings PowerScan™ PD9330...
  • Page 27: Reading Parameters

    Move the reader toward the target and center the aiming spot, then pull the trigger to capture and decode the bar- code. See Using the PowerScan™ PD9330 on page 4 more information. The aiming system will switch off after the acquisition time.
  • Page 28: Operating Modes

    Flash On time. Double Read Timeout pre- vents undesired multiple reads. See the Product Reference Guide (PRG) for these and other programmable features Controlled by Flash On Time and Flash Off Time. Use the PRG to program these options. PowerScan™ PD9330...
  • Page 29: Multiple Label Reading

    Operating Modes Scan Mode (continued) ENTER/EXIT PROGRAMMING MODE Scan Mode = Trigger Single Scan Mode = Trigger Pulse Multiple Scan Mode = Trigger Hold Multiple Scan Mode = Flashing Scan Mode = Always On Multiple Label Reading The reader offers a number of options for multiple label reading.
  • Page 30: Technical Specifications

    45 mA @ 4.5 V 45 mA @ 4.5 V Idle/Standby 40 mA @ 5 V 40 mA @ 5 V (typical) 20 mA @ 12 V 20 mA @ 12 V 12 mA @ 30 V 12 mA @ 30 V PowerScan™ PD9330...
  • Page 31 Technical Specifications Performance Characteristics Light Source Laser PD9330 PD9330-AR Roll (Tilt) Tolerance ± 35° ± 10° Pitch Tolerance ± 40° ± 60° Skew (Yaw) Toler- ± 65° ± 65° ance Print Contrast Mini- 25% minimum reflectance Maximum 3 mils 7.5 mils Resolution 104 (±...
  • Page 32 Full ASCII, Code39 CIP, Code 32, Codabar, Interleaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI, Plessey, Code 93, Follet 2/5, Code 4, Code 5, Datalogic 2 of 5, Codablock F PD9330-AR GS1 Databar linear codes, UPC/EAN, UPC/EAN P2/P5 Addons,...
  • Page 33: Led And Beeper Indications

    LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s func- tions are programmable, and so may or may not be turned on.
  • Page 34 Green Spot ware shall turn flashes the green spot momentarily on for the time specified by the configured value. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected PowerScan™ PD9330...
  • Page 35 LED and Beeper Indications Programming Mode The following indications ONLY occur when the reader is in Programming Mode INDICATION DESCRIPTION BEEPER Label Pro- A valid program- Reader sounds LED blinks four low fre- gramming ming label has continuously Mode Entry been scanned.
  • Page 36: Cleaning

    Do not use abrasive or aggressive cleansing agents or abrasive pads to clean scan win- dows or plastics. Do not spray or pour liquids directly onto the CAUTION unit. PowerScan™ PD9330...
  • Page 37: Datalogic Adc Limited Factory Warranty

    Datalogic service center, with shipping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Da-...
  • Page 38: Warranty Exclusions

    No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic. DATALOGIC' S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATU- TORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT.
  • Page 39: Ergonomic Recommendations

    Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of specific writ- ten instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
  • Page 40: Services And Support

    Services and Support Services and Support Datalogic provides several services as well as technical sup- port through its website. Log on to www.datalogic.com click on the links indicated for further information. Products Search through the links to arrive at your product page where...
  • Page 41 Services and Support NOTES Quick Reference Guide...
  • Page 42 Services and Support NOTES PowerScan™ PD9330...
  • Page 43 Services and Support NOTES Quick Reference Guide...
  • Page 44 Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. PowerScan is a trademark of Datalogic S.p.A. or of Datalogic Group companies, registered in many countries, including the U.S. and the E.U.

Table of Contents