Ttl Baud Rate; Ttl Master Output; Ttl Response Time - Toshiba Q7 Installation And Operation Manual

Table of Contents

Advertisement

TTL Baud Rate

TTL Baud Rate
Program
Comm Settings
This parameter plays a role in the setup of the communications network by
establishing the Baud Rate of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
1200
2400
4800
9600
19200
38400

TTL Master Output

Program
Comm Settings
In a master/follower configuration, this setting determines the output parameter
of the master ASD that will be used to control the applicable follower ASDs.
Note: Select Normal if RS485 Master Output is configured as a
Master Output controller. Otherwise, a keypad failure will
result.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
Normal
Frequency Reference
Output (Commanded) Frequency
Torque Command
Output Torque (Command)

TTL Response Time

Program
Comm Settings
This parameter sets the TTL response delay time.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Q7 ASD Installation and Operation Manual
TTL Baud Rate
TTL Master Out
TTL Res Time
TTL Response Time
Parameter Type — Selection List
Factory Default — 9600
Changeable During Run — Yes
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 2.00
Units — Seconds