Function Switching] Switching Of Allocation And Functions Of Input Terminals - Mitsubishi FX3G SERIES User Manual

Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3G
User's Manual - Hardware Edition

11.8.2 [Function switching] switching of allocation and functions of input terminals

When the counters C248, C253 and C254 are combined with the following special auxiliary relays, the
allocation of the input terminals and functions are changed.
Program the special auxiliary relays just before the counters.
Counter No.
C248(OP)
C253(OP)
C254(OP)
Function switching method
M8388
M8392
C248
K
M8388
M8392
C253
K
M8388
M8395
C254
K
11 Use of High-speed Counters
11.8 Related Devices and Function Switching Procedures
Details of change
Reset input is not given.
Reset input is not given.
The input count (2-phase 2-count) changes as follows
Phase A : Changes from X000 to X006.
Phase B : Changes from X001 to X007.
Reset input is not given.
Start input is not given.
11
12
13
14
15
16
17
18
19
20
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents