3.3 Operation in Top View Mode

When the inverter is powered on, it enters this mode first, which allows you to monitor the operating status, set an
operation frequency, use EASY key, and switch between languages.
When Panel Jog Run is selected, a jog run frequency also can be specified in this mode.
Explanation of the top window
• Display of commands executed:
"FWD" or "REV" is displayed to indicate the direction of rotation.
The operation frequency is displayed in the form of "
• Display of operating status:
"RUN" is displayed during operation.
"STOP" is displayed during a stop.
"Trip" is displayed in the event of tripping.
• Display of output frequency:
The operation frequency is displayed in the form of "
• Display of alarm/trip:
In case of alarm or trip, Its code is displayed.
• Display of alarm/trip information:
In case of alarm or trip, Its information is displayed.
Functions of function keys
: Switches between Quick mode and Standard Setting mode.
F1
: Goes to the Language selection window.
F2

3.3.1 Setting a panel operation frequency

Only when Frequency input mode selection 1 (parameter "FMOd") is set at "4", panel operation frequency setting is
activated.
1. Press the control dial.
The panel frequency window appears.
The current operation frequency setting is displayed at the center
of the window.
The current output frequency is displayed in the upper right section
of the window.
The minimum allowable frequency (min) and the maximum
allowable frequency (max) are displayed at the bottom of the
window.
Functions of function keys
The functions keys allow you to select the position or decimal place
of each figure (operation frequency) you want to increment or
decrement with the control dial.
: Selects the position of 1000 times of minimum setting unit.
F1
: Selects the position of 100 times of minimum setting unit.
F2
: Selects the position of 10 times of minimum setting unit.
F3
: Selects the position of minimum setting unit (In this case, 0.1).
F4
Display of commands
executed
.
Hz".
FWD 60.0 Hz
.
Hz".
Quick
F1
Display of output frequency
Display of alarm/trip
Output frequency
min=0.0
×1000
F1
C-3
E6581429
Display of
operating status
Top View Mode
RUN
60.0
Hz
Overheat alarm
Lng
---
F2
Display of alarm/trip
message
Basic Parameters
FC
Panel frequency
0.0
Hz
0.0Hz
max=60.0
×100
×10
×1
F2
F3
F4
3