000
80
7. Appendix
ND Filter Dial
If the ND filter will not move, you can move the
filter to the Clear position manually using the
following procedure.
1
Turn the camcorder POWER switch to the off
position.
2
Remove the round cap on the bottom side.
3
Insert a screwdriver in the hole and turn it
counterclockwise.
ˎ The ND filter moves to the Clear position by
ˎ
turning counterclockwise. Continue turning
until reaching the Clear position.
ˎ Use a screwdriver with Ø2.4 mm diameter
ˎ
or smaller. The insertion depth of the
screwdriver is about 3.2 cm (1 5/16 in.).
Screwdriver hole
(with cap removed)
4
Set the PRESET/VARIABLE switch (page 6)
to the PRESET position, and set the ND FILTER
dial (page 6) to Clear.
[Notes]
ˎ Do not use the procedure above during normal operation.
ˎ
Only use this procedure if the ND filter will not move. The
ND filter may become damaged if this procedure is used
during normal operation.
ˎ After the procedure above is used, consult a Sony service
ˎ
center to have the camcorder repaired.
ˎ If an error message still appears after performing the
ˎ
procedure above, shooting is still possible.