Adjusting The Exposure; Adjusting The Light Level (Nd Filter) - Sony PXW-Z90T Operating Manual

Solid-state memory solid-state memory camcorder
Table of Contents

Advertisement

Adjusting the brightness (Continued)
• When recording under fluorescent lamps,
sodium lamps, or mercury lamps, the picture
may flicker or change colors, or may have
horizontal bands of noise.
You may be able to improve the situation by
adjusting the shutter speed to 1/100 if the power
frequency of your area is 50 Hz, or 1/60 in a 60
Hz area.
• You can switch the shutter speed display
between seconds and degrees ([SHUTTER
DISPLAY], p. 124).
To adjust automatically
Press the SHUTTER SPEED button D
while the shutter speed value is highlighted.
The shutter speed value disappears, or
appears next to the shutter speed value.
When AE is fixed,
Setting when [60i/50i SEL] is switched
The shutter speed may change after
switching, depending on the current speed
level. Refer to the following table for the
shutter speed levels.
Level
60i/60p/30p
0
1
8
2
15
3
30
4
50
5
60
6
90
7
100
8
125
9
180
10
250
11
350
12
500
13
725
14
1000
15
1500
16
2000
17
3000
46
appears.
24p
50i/50p/25p
6
12
6
24
12
25
25
40
30
48
50
50
60
60
100
96
120
100
150
120
215
144
300
192
425
200
600
288
1000
400
1250
576
1750
1200
2500
Level
60i/60p/30p
18
4000
19
6000
20
10000

Adjusting the exposure

AUTO (
)
MANUAL (all)
1 When you switch to AUTO/MANUAL
in [SPOT METER] or [SPOT METER/
FOCUS].
2 When all of iris, ISO sensitivity/gain,
and shutter speed are set to MANUAL.
3 When the last setting of the exposure is
set to AUTO, and the iris, ISO sensitivity/
gain, or shutter speed is set to AUTO.
4 When the last setting of the exposure is
set to MANUAL, and the iris, ISO
sensitivity/gain, or shutter speed is set to
AUTO.
b Note
• When you set the AUTO/MANUAL switch F
to AUTO, or press [EXEC] on the [SPOT
METER] or [SPOT METER/FOCUS] screen,
the exposure is returned to AUTO.
Adjusting the light level (ND
Filter)
You can set an appropriate brightness level
using the ND filter switch E when the
recording environment is too bright.
The ND filters 1, 2 and 3 reduce the light
level to about 1/4, 1/16 and 1/64,
respectively.
If
flashes during the iris automatic
adjustment, set the ND filter to 1. If
flashes during the iris automatic
24p
50i/50p/25p
2400
3500
4800
6000
10000
10000
MANUAL (
)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxw-z90v

Table of Contents