Lenovo Flex System x480 X6 Compute Node Installation And Service Manual page 357

Hide thumbs Also See for Flex System x480 X6 Compute Node:
Table of Contents

Advertisement

1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
8007030d-2582ffff : Sensor [SensorElementName] has transitioned to non-recoverable from
a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable from less severe.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0524
User Response
RAID Vol State :
8007030d-2b81ffff : Sensor [SensorElementName] has transitioned to non-recoverable from
a less severe state.
The FlashDIMM agent has indicated Compute Book 1 contains a FlashDIMM with Less than 10% write
warranty remaining
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0524
User Response
Information only; warranty is about to expire but no action is required.
.
Chapter 6
Troubleshooting
347

Advertisement

Table of Contents
loading