Gas Supply - Wolf OG30 Installation Manual

Hide thumbs Also See for OG30:
Table of Contents

Advertisement

Available languages

Available languages

SPE C IF I CAT I ON S

Gas Supply

Installation must comply with local codes or, in the absence
of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the
illustrations on pages 7–8.
The outdoor grill is equipped for use with natural or liquid
propane (LP) gas. It is design certified by the Canadian
Standards Association (CSA) for natural or LP gases. The
product rating plate has information on the type of gas that
should be used. For rating plate location, refer to the illustra-
tion below. If this information does not agree with the type
of gas available, check with the local gas supplier.
GA S REQ U IR EM EN T S
NAT U R A L G AS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
L P G AS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
RATING PLATE
Outdoor gas grill.
|
6
Wolf Customer Care 800.222.7820
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
RATING PLATE
Outdoor module.
The outdoor grill must be connected to a regulated gas
supply. The supply line must be equipped with an approved
external gas shut-off valve located near the grill in an acces-
sible location. Do not block access to the shut-off valve.
Refer to the illustration below.
A gas supply line of
3
/
"
(19)
4
the outdoor grill or module. If local codes permit, a certified,
3'
long,
1
/
"
or
3
/
"
(.9 m)
(13)
2
4
connector is recommended to connect the units
female inlet to the gas supply line. Pipe joint compounds,
suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of .5 psi
. The appliance must be isolated from the gas
(3.5 kPa)
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test
pressures equal to or less than .5 psi
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.
rigid pipe must be provided to
ID flexible metal appliance
(19)
1
/
" NPT
2
.
(3.5 kPa)