For Service - Cornelius IACSSO Use And Care Manual

Table of Contents

Advertisement

If you need service or assistance, we suggest
you follow these steps:
Before calling for service . . .
Performance
problems
often result from little things
you can find and fix yourself,
without
tools of any
kind.
Unit does not run:
l
Cycle Control
Knob must be in the "ON" position.
l
Check
to see that the power
cord is plugged
in.
l
Check
for a blown
fuse or tripped
circuit breaker
in the electrical
supply
to the machine.
l
Room temperatures
must be above
55°F (13°C).
Otherwise,
the Bin Thermostat
may sense a cold
room temperature
and shut off even though
the
storage
bin is not full of ice. Also, the unit may not
restart once it does shut off.
Unit runs but does not produce
ice:
l
Cycle Control
Knob must be in the "ON" position.
l
Check
water supply
to make sure it is open.
l
If ice machine
is operated
at an elevation
above
2000 feet above
sea level, both the Bin Thermo-
stat and the Ice Thickness Thermostat
need to be
recalibrated.
See Installation
Instructions.
Unit runs but produces
very little ice:
l
Room temperature
may be extremely
high (over
90°F (32°C)). In this case, it is normal
for ice
production
to be low.
l
Dirt or lint may be blocking
the airflow through
the finned condenser.
Condenser
needs to be
cleaned.
l
Check
to see if the unit has a scale buildup
in the
water and/or
freezing
systems. Clean them, if
necessary.
Grid is not cutting
ice sheets:
l
Check
the grid harness plug to make sure the
connection
is secure.
Off taste
in ice cubes:
. There may be an unusually
high mineral
content
in the water supply.
Water may need to be
filtered
or treated.
l
Do not store any foods in the ice bin.
l
Packaging
materials
are not all removed.
10