3. BB Circuit Technical brief
3.2.3 RF Interface(T_OUT)
S-Gold3H-LC uses this interface to control RF IC and Peripherals.
[Table 3.2.3-1] RF Interface Spec.
T_OUT
Resource
T_OUT0
T_OUT1
T_OUT2
T_OUT3
T_OUT4
T_OUT5
T_OUT6
T_OUT7
T_OUT8
T_OUT9
T_OUT10
LGE Internal Use Only
Interconnection
TXON_PA
ANT_SEL1
PA_MODE
ANT_SEL2
ANT_SEL3
- 18 -
GM310f service manual
Description
PAM Power on
-
FEM control
PAM Mode select
FEM control
FEM control