Fig.
4-2
Fig. 4-3
Purity control
1 ,
L e c t s this area,
Deflection yoke positioning
corrects these areas.
4-3.
CONVERGENCE
ADJUSTMENT
Preparation :
Before starting this adjustment, adjust the focus. horizontal
size and vertical size.
*
Set the Picture Mode to "STANDARD".
-
Cross hatch
/
Dot pattern.
4-3-1, Horizontal
and
Vertical Static Convergence
C Board
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center
of the screen.
2. (hloving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the center
of the screen.
3. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.ST,AT variable resistor and
the V.STAT magnet in the manner given below.
(In
this case. the H.STAT variable resistor and the V.STAT
magnet influence each other. so be sure to perform adjust-
ments while tracking.)