11.1.3. Service Function Table

Code
Function
501
Pause time set
503
Dial speed select
507
V34 transmission start speed
508
V34 reception start speed
514
Bell signal detect time
520
CED frequency select
521
International mode select
522
Auto standby select
523
Receive equalizer select
524
Transmission equalizer select
527
V.8 function select
529
Call Service Clear
550
Memory clear
551
ROM check
552
DTMF signal tone test
553
Monitor
on
FAX
select
554
Modem test
555
Scanner test
556
Motor test
557
LED test
558
LCD test
561
KEY test
567
T0 timer
570
BREAK% select
573
Remote turn-on ring number set
574
Dial tone detect check
590
FAX auto redial time set
591
FAX auto redial line disconnection
time set
Set Value
X 100 msec
1:10 pps
2:20 pps
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
X 100msec
1:2100 Hz
2:1100 Hz
1:ON / 2:OFF
1:ON / 2:OFF
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1:OFF / 2:ON
1:ON / 2:OFF
communication
1:OFF
2:PHASE B
3:ALL
X second
1:61% / 2:67%
/ 3:63%
X number of
rings
1: ON / 2: OFF 1, 2
X number of
times
X second
KX-MB1520FX7/KX-MB1520FX8/KX-MB1520FXW/KX-MB1530FX7/KX-MB1530FXW
Effective
Default
Range
001~600
030
----------
1, 2
1
----------
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
0~8
1
If the code 527 is set at 2, the code 507 and 508
work.
1~9
6
----------
1, 2
1
See How To Output The Journal Report (P.160).
1, 2
1
See How To Output The Journal Report (P.160).
1, 2
1
The resolution reverts to the default when transmis-
sion is complete.
1~4
1
Set RX equalizer to automatic mode.
1~4
1
1, 2
2
Refer to Memory Clear Specification (P.105).
See Test Functions (P.98).
1, 2
2
See Test Functions (P.98).
1~3
1
Sets whether to monitor the line signal with the
unit's speaker during FAX communication or not.
See Test Functions (P.98).
See Test Functions (P.98).
0
See Test Functions (P.98).
See Test Functions (P.98).
See Test Functions (P.98).
See Test Functions (P.98).
001~255
052
Sets a higher value when the response from the
other party needs more time during automatic FAX
transmission.
1, 2, 3
1
Sets the% break of pulse dialing according PBX.
00~99
10
Sets the number of rings before the unit starts to
operate TAM in the TEL mode.
2
----------
00~99
05
Selects the number of redial times during FAX com-
munication (not including the first dial).
001~999
65
Sets the FAX redial interval during FAX communi-
cation.
103