Re-Installation - Toshiba MMU-AP0071MH Owner's Manual

Hide thumbs Also See for MMU-AP0071MH:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
The slot provided at side surface of the outdoor
unit is an air intake for cooling the electrical parts.
If the air intake would be clogged, a trouble is
caused on the electrical parts.
Therefore never close the air intake or do not
place any obstacle near the air intake.
Air conditioner operating conditions
For the specified performance, operate the air conditioner under the following temperature conditions:
Cooling operation
Outdoor temperature : –5°C to 43°C (Dry-bulb temp.)
Room temperature
CAUTION
Heating operation
Outdoor temperature : –15°C to 15.5°C (Wet-bulb temp.)
Room temperature
If air conditioner is used outside of the above conditions the units, safety protection devices may operate.

RE-INSTALLATION

If the unit position is to be changed and re-located to a new position ask your local dealer or instal-
lation specialist. Do not attempt to move the air conditioner yourself, as incorrect installation may
cause electric shock or fire.
Do not install the air conditioner in the following places
• Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed
in such places, noise transmitted from the air conditioner may effect the operation of these appliances.
• Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business
use, etc.), as the air conditioner may malfunction.
• Do not install the air conditioner in a humid or oily place, or in a place where steam, soot, or corrosive gas
may be generated.
• Do not install the air conditioner in a salty place such as a seaside area.
• Do not install the air conditioner in a place where a great deal of machine oil is used.
• Do not install the air conditioner in a place where it is usually exposed to strong winds such as in a seaside
area or on the roof / upper floor of a building.
• Do not install the air conditioner in a place where sulfureous gas may be generated such as in a spa.
• Do not install the air conditioner in a vessel or mobile crane.
Be careful with noise or vibrations
• Do not install the air conditioner in a place where the noise or the hot air created by the outdoor unit will
come into contact with your neighbours.
• Install the air conditioner on a solid and stable foundation as this will reduce the transmission of noise and
vibration that is produced from the outdoor unit.
• If one indoor unit is operating, some sound may be audible from other indoor units that are connected within
the same system (even when not in operation).
: 21°C to 32°C (Dry-bulb temp.), 15°C to 24°C (Wet-bulb temp.)
Room relative humidity – less than 80 %. If the air conditioner operates
in excess of this figure, the surface of the air conditioner may cause dewing.
: 15°C to 28°C (Dry-bulb temp.)
DANGER
23
Slot for air intake