Husky FP2021 Operating Instructions Manual

Portable aircompressors

Advertisement

Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable permanently lubricated air
compressors are for home and
workshop use. All models are equipped
with regulators, needle and ball
bearings, and motors with automatic
overload protection. Draining moisture
from the air receivers is required
maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.

General Safety

Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up a
high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
WARNING
!
should be done by a
qualified (licensed or certified)
electrician. On a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
1. Read instruction manuals for each
component carefully, before
attempting to assemble,
disassemble or operate your
particular system.
2. Do not exceed pressure rating of
any component in system.
3. Protect material lines and air lines
from damage or puncture. Keep
hose and power cord away from
sharp objects, chemical spills, oil,
solvents, and wet floors.
4. Never point a spray gun at oneself
or any other person. Accidental
discharge may result in serious
injury.
5. Check hoses for weak or worn
condition, before each use, making
certain all connections are secure;
do not use if deficiency is found.
Notify an authorized service facility
for examination or repair.
Portable Air
Compressors

Breathable Air Warning

This compressor/pump is not
equipped and should not be used
"as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment. This
additional equipment is
necessary to properly filter and
purify the air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not simultaneously
used, existing warranties shall be
voided, and Husky disclaims any
liability whatsoever for any loss,
personal injury or damage.
6. Release all pressures within system
slowly; dust and debris may be
harmful.
WARNING
!
system before servicing air compressor!
(Turn pressure regulator knob fully
clockwise after shutting off
compressor).
FP2021
DANGER
!
Disconnect power
and depressurize
IN605000AV 3/02

Advertisement

Table of Contents
loading

Summary of Contents for Husky FP2021

  • Page 1: General Safety

    MAY result in minor or sharp objects, chemical spills, oil, voided, and Husky disclaims any moderate injury. solvents, and wet floors. liability whatsoever for any loss, Notice indicates NOTICE 4.
  • Page 2: Installation

    Portable Air Compressors Overheating, short provides safety against over General Safety CAUTION circuiting and fire pressure. (Continued) damage will result from inadequate 23. Do regular maintenance; keep all wiring, etc. nuts, bolts, and screws tight, to be 7. Follow all local electrical and safety sure equipment is in safe working EXTENSION CORDS codes, as well as the National...
  • Page 3: For Trouble-Free Operation

    FP2021 Wire and Terminal Guide Installation Wire Color Terminal (Continued) Power cord White Line 2. If repair or replacement of cord or Motor cord White Load plug is necessary, do not connect Power cord Black Line grounding wire to either flat blade...
  • Page 4: Maintenance

    Portable Air Compressors 2. Pull ring on safety valve and allow it to IMPORTANT: Unit should be located as far Operation snap back to normal position. from spraying area as hose will allow. (Continued) LUBRICATION 4. Fully counterclockwise will shut off flow This is a compressor that requires no of air completely.
  • Page 5 FP2021 Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Fuses blow/circuit 1. Incorrect size fuse, circuit overloaded 1. Check for proper fuse, use time-delay fuse. breaker trips repeatedly Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2.
  • Page 6 Portable Air Compressors Limited Warranty - Husky Air Compressors, by Campbell Hausfeld 1. DURATION: From the date of purchase by the original purchaser as follows: Standard Duty - One Year. 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400 3.
  • Page 7: Directives De Sécurité

    1. Lire attentivement tous les manuels qui RÉSULTERA en perte de vie ou simultanément, les garanties en blessures graves. d’instructions pour chaque pièce existance seront annulés, et Husky nie Avertis- détachée avant d’esssayer de toute responsabilité pour n’importe AVERTISSEMENT sement monter, démonter ou de faire...
  • Page 8 Compresseurs d’Air Portatifs Généralités sur la 22. NE JAMAIS rajuster la soupape de fils insuffisant peut causer le surchauffage, court-circuit et le sûreté ou le manostat. Garder la Sécurité (Suite) dommage d’incendie. soupape de sûreté libre de peinture et autres accumulations. Ceci sert à CORDONS PROLONGATEURS le Occupational Safety and Health éviter la sur-pression.
  • Page 9 FP2021 Guide de Fils et Bornes Installation (Suite) Couleur Borne Chaud REMARQUE: Ne pas utiliser un raccord de Cordon d’alimentation Blanc Ligne mise à la terre. Cordon du moteur Blanc Charge 2. Si la réparation ou le remplacement du Cordon d’alimentation...
  • Page 10: Entretien

    Compresseurs d’Air Portatifs 2. Tirer la bague sur la soupape de Fonctionnement pulvérisation que le tuyau flexible sûreté et la permettre de retourner à permettra. (Suite) la position normale. GRAISSAGE 4. Tourner complètement au sens invers Ceci est un compresseur qui ne requiert des aiguilles d’une montre afin de aucune lubrification additionnelle.
  • Page 11 FP2021 Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesures Correctives Fusibles sautés/le 1. Taille de fusible incorrect, surcharge 1. Vérifier le type de fusible, utiliser un fusible à disjoncteur se retardement. Débrancher les autres appareils déclenche à maintes électriques du circuit ou faire fonctionner le reprises compresseur sur un circuit unique.
  • Page 12 Compresseurs d’Air Portatifs Garantie Limitée - Compresseurs d’air Husky, par Campbell Hausfeld 1. DURÉE: À partir de la date d’achat par l’acheteur original comme suit: Produits À Service Standard (Standard Duty) - Un An. 2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 3.
  • Page 13 Mantenga la manguera y el cable anularán y la compañía Husky no gravedad. de corriente alejados de objetos asumirá NINGUNA responsabilidad filosos, derrames de productos Ésto le...
  • Page 14: Instalación

    Compresores de Aire Portátiles preferible que use mangueras de aire insecticidas u otras substancias Generales de Seguridad adicionales en vez de cordones de inflamables. (Continuación) extensión para extender el alcance. 21. Use un respirador para rociar. ALAMBRADO 22. NUNCA modifique la válvula de electricidad y seguridad locales y 1.
  • Page 15: Para Evitar Problemas

    FP2021 Guía de cables y terminales Instalación Cable Color Terminal Con tensión (Continuación) Cordón eléctrico Blanco Línea cable de desvio a la corriente Cordón del motor Blanco Tensión eléctrica. Este producto tiene un Cordón eléctrico Negro Línea cordón con un alambre y terminal de Cordón del motor...
  • Page 16: Mantenimiento

    Compresores de Aire Portátiles 4. Apague el compresor (póngalo en Funcionamiento 2. Cerciórese de que el manómetro esté OFF ) y limpie completamente el en ZERO antes de cambiar de (Continuación) motor, tanque, líneas de aire y las herramientas neumáticas o aletas de enfriamiento del cabezal.
  • Page 17 FP2021 Guía de Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a Tomar Compresor no funciona 1. Pérdida de potencia o se 1. Chequee el cordón de extensión adecuado (vea la sobrecalienta sección CORDONES DE EXTENSION, página 3) 2. No hay energía eléctrica 2.
  • Page 18 Compresores de Aire Portátiles Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar La presión del tanque 1. Conecciones flojas (coneciones, 1. Chequée todas las conecciones con agua enjabonada disminuye cuando el tuberías, etc.) y apriete las conecciones flojas compresor se apaga 2.
  • Page 19 FP2021 Garantía Limitada - Compresores de Aire Husky, de Campbell Hausfeld 1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Productos Estándard (Standard Duty) - Un año. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400...

Table of Contents