Slide 65
5. Engine
Ricoh Europe B.V.
Technical Training Centre

Fusing Unit AC Power Control

The fusing lamp is heated with AC power and is
controlled by a triac (THY1).
"On/Off control" is achieved when the gate of the
triac is turned on/off by a phototriac (PC1).
The Phototriac also acts as an isolating part.