System 75, System 85, and DEFINITY Systems

This phone must be administered as a 7303s Hybrid terminal for the following systems:
System 75 - R1V1, R1V2, and R1V3
System 85 - R2V1, R2V2, R2V3, and R2V4
DEFINITY G1 - (R1V4)
DEFINITY G2 - G2.1 and G2.2 - (R2V5, R2V6)
DEFINITY G3 Version 1 - (R1V5)
DEFINITY G3 Version 1.1 and Version 2
Native terminal administration is provided in DEFINITY G3 Version 3.
On the older switch types that do not accommodate Universal modules (System 85 - R2V1,
R2V2, R2V3, and R2V4), an ANN17B Hybrid pack in conjunction with a DS-1 carrier must
be used to connect the switch and the MDW 9010 telephone. On the newer switches that
accommodate Universal modules:
System 75 - R1V1, R1V2, and R1V3
DEFINITY G1 - (R1V4)
DEFINITY G3 Version 1 - (R1V5)
DEFINITY G3 Version 1.1 and Version 2
DEFINITY G3 Version 3
A TN762B Hybrid pack must be used with the Universal carrier for this purpose. Depending
upon the actual hardware configuration, DEFINITY G2 - G2.1 and G2.2 may utilize either an
ANN17B or TN762B pack. In either case, the latest vintage packs are recommended.
Note that for DEFINITY G2.1 and G2.2, General Terminal Administration (GTA) may be used
to set up "custom" set types so that administration may be done using that custom set type.
Set administration and button feature assignment may be done only by the system
administrator. It is recommended that you do not use features that require visuals (the
LCD feature indicator) to be updated while the set is turned off. Also, since some features,
such as Send All Calls, provide visual indication that the feature is turned on, be aware
that if you turn off the handset when using that feature, you may forget that the feature is
on.
System 75 and DEFINITY G1 and G3 system buttons should be assigned as follows:
1, 2, 3, 4, and 5 are line or feature buttons: