Gt Series Error Codes - Panasonic GTWIN Reference Manual

Hide thumbs Also See for GTWIN:
Table of Contents

Advertisement

GTWIN Reference Manual

6.3 GT Series Error Codes

An error code is displayed in the upper right corner of the GT screen when an error occurs.
Error code
Error
**00FF
Time up error
**0100
Keyboard screen data parts
digit error
**0101
Alarm history error
**0500
Tool setting error
**1000
SD memory card not
inserted
**1001
SD memory card writing
error
**1002
SD memory card memory
full
**1003
SD memory card reading
error
**1005
SD memory card saved file
name error
**1006
SD memory card
recognition error
**1020
Noncompatible PLC
program error
**1021
Unsupported PLC model
error
**1022
Password protection error
**1023
Master memory error (FP-X
only)
**1025
General-purpose memory
shortage
**1027
Remote mode error
(FP2/FP2SH only)
Cause and solution
 The PLC connection cable is disconnected. Check the cable.
There is a temporary error due to noise, etc. Resupply power
to the PLC and GT touch panel.
Check that the digit of the data parts on the keyboard screen has
been set correctly.
When updating the alarm history display is stopped, the alarm
history data displayed on the GT screen has been stored in the
memory. When the stop display update is canceled, new data is
displayed.
A device that does not exist in the selected PLC model is
specified. Correct.
The SD memory card is not properly inserted into the SD memory
card slot.
Data cannot be written to the SD memory card. Make sure the SD
memory card is not write-protected.
Delete some data on the SD memory card or prepare a new SD
memory card.
The SD memory card cannot be read. Use a PC to check whether
the data saved on the SD memory card has been damaged.
You have not specified the file name to be saved on the SD
memory card from the GT touch panel properly. Specify a proper
file name.
The SD memory card is not recogized. Check the SD memory
card.
The PLC program to be transferred uses commands, etc. not
supported by the destination PLC.
Rewrite the program so that it can be supported by the destination
PLC.
The selected PLC model is not supported.
 An incorrect password has been input three times or more.
Turn the power supply off and on again and then input the
correct password.
 Upload protection has been turned on for the PLC.
The number of digits was changed when a new password with
the FP monitor function was set. Cancel the password setting
before changing the number of digits.
A master memory has been installed in the FP-X. It is not possible
to transfer programs from an SD memory card to a PLC with the a
master memory.
There is not enough general-purpose memory available in the
destination PLC.
The PLC is set to RUN mode. Change to REMOTE mode or
PROG. mode.
6.3 GT Series Error Codes
219

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents