Electrical Adjustments; Fan Voltage Adjustment - Sanyo PLC-XP56 Service Manual

Model plc-xp56l does not provide projection lens.
Hide thumbs Also See for PLC-XP56:
Table of Contents

Advertisement

■ Electrical Adjustments

* Following information differs from the previous chassis No. MR3-XP5500, others are the same;
- The fan voltage adjustment has been changed.
❈ Different items as below:
c

Fan Voltage adjustment

1. Enter the service mode.
2. Connect a digital multimeter to test point "
and chassis ground (-). (as shown below)
11
3. Select group no. "
", item no. "
value of the fan number. (as shown below)
41
4. Select item no."
" and change data value to adjust
the fan max. output voltage to be
42
5. Select item no."
" and change data value to adjust
the fan min. output voltage to be
6. Each fan should be adjusted refer to item 2 - 5.
Note:
The location of each fan is refer to the parts list.
FAN No.
Group/Item
FN901
11 / 24
FN902
11 / 24
FN903
11 / 24
FN904
11 / 24
FN905
11 / 24
FN906
11 / 24
FN907
11 / 24
TPFN❊
" (+)
24
" and change data
14.0
±0.1V.
6.5
±0.1V.
Data
Test point
0
TPFN1
0
TPFN1
2
TPFN3
5
TPFN4
1
TPFN5
4
TPFN6
3
TPFN7
-6-