Power supply cord,
4-wire connection:
IMPORTANT: A 4-wire connection is
required for mobile homes and where local
codes do not permit the use of 3-wire
connections.
B
A
C
D
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals
1. Remove center terminal block screw.
2. Remove neutral ground wire from
external ground conductor screw.
Connect neutral ground wire and
the neutral wire (white or center wire)
of power supply cord under center
terminal block screw. Tighten screw.
A
B
A. External ground conductor screw - Dotted line shows position
of NEUTRAL ground wire before being moved to center
terminal block screw.
B. Center terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
16
F
E
C
D
E
3. Connect ground wire (green or bare) of
power supply cord to external ground
conductor screw. Tighten screw.
A
B
C
G
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4" (19 mm) UL listed strain relief
D. Center terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal
block screws. Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with holddown screw.
7. You have completed your electrical
connection. Now go to "Venting
Requirements."