Sanitizer Output Led Indicators; More And Less Output Buttons; Self-Cleaning - Pentair IC60 Installation And User Manual

Electronic chlorine generator
Table of Contents

Advertisement

8
Operator Control Panel (continued)

Sanitizer Output LED Indicators

The five (5) LED indicators display as a bar graph to show in 20% increments, the percentage of time the
chlorine is produced per hour of pump run time. In BOOST mode, these LEDs (blink from left to right).
Note: If no LEDs are lit, the output is set to 0% and the IntelliChlor Electronic Chlorine Generator is
not producing chlorine.
• 0% - No LEDs lit - No chlorine produced - IntelliChlor Electronic Chlorine Generator is off.
• 20% - 1 LED lit - Produces chlorine 20% of each hour of pump run time, 12 minutes on, 48 minutes off.
• 40% - 2 LEDs lit - Produces chlorine 40% of each hour of pump run time, 24 minutes on, 36 minutes off.
• 60% - 3 LEDs lit - Produces chlorine 60% of each hour of pump run time, 36 minutes on, 24 minutes off.
• 80% - 4 LEDs lit - Produces chlorine 80% of each hour of pump run time, 48 minutes on, 12 minutes off.
• 100% - 5 LEDs lit - Produces chlorine almost 100% of each the hour of pump run time, 59 minutes on, 1 minute off.
Note: If connected to an IntelliTouch, EasyTouch or SunTouch system, these lights may slowly flash
when the output is set to a value not exactly 20%, 40%, 60% 80% or 100%. Example: 21% output
setting from the IntelliTouch, EasyTouch or SunTouch will flash the 20% light.

More and Less Output Buttons

The More and Less buttons control the percentage of time of each hour that the IntelliChlor Electronic
Chlorine Generator is producing chlorine while the pump is on (see Sanitizer Output LED indicators above).
The lights act as a bar graph: the more lights that are on, the more that chlorine is produced. Slide the panel
cover up to access the More, Less and Boost On/Off buttons. To exit Boost mode, press and hold both the
More and Less buttons. Note: When a IC20, IC40 or IC60 is connected to an IntelliTouch®,
EasyTouch® or SunTouch® system, the Less and More buttons are disabled and IntelliChlor Sanitizer
Output is controlled externally.
More:
Increases the time the cell produces chlorine, in 20% increments. Example: The Sanitizer Output
display is showing 20%. Pressing the MORE button once will turn on the 40% light. The unit will produce
chlorine 40% of each hour the IECG is on. Pressing MORE again will turn on the 60% light, and so on until
all five (5) lights are on.
Less:
Decreases the time the cell produces chlorine, in 20% increments. Example: The Sanitizer Output
display is showing 40%. Pressing the LESS button once will turn off the 40% light, leaving only the 20%
light. The unit will produce chlorine 20% of each hour the IECG is on. Pressing LESS again will turn off the
20% light, leaving no lights on, no chlorine is produced.
Press and hold both the More and Less buttons together to activate Boost mode on or off.
Boost On/Off:
Boost mode sets the sanitizer output to run 100% for the next 24 hours of pool pump run time. If the time
clock switches off the pump cycle, then switches power back on the next day, Boost mode will continue until
24 hours has elapsed since Boost mode was turned on or Boost mode is canceled by the user. The Sanitizer
Output display will show a pattern LED display to indicate Boost mode.

Self-Cleaning

The self-cleaning feature reduces scale buildup on the blades of the IECG. The self-cleaning cycle tends to
reduce the life of the IECG, therefore, it should be used only to the extent necessary to minimize the scale
buildup on the blades. The self-cleaning cycle can be adjusted to run every 2, 3, 4, or 5 hours, whichever is the
optimal for your particular pool conditions in order to minimize scale buildup but maximize the life of the IECG.
It is factory set to two (2) hours for the first 30 days of operation, then automatically switches to three (3)
hours. To change the self-cleaning cycle, press and hold the LESS button for three (3) seconds. The sanitizer
output display will show the number of hours in a bar graph style. The number of output LEDs lit is the number
of reverse hours. Pressing More or Less button will change this setting.
run for four (4) hours and the pool owner chooses to change it to three (3) hours to optimize the blade cleaner cycle for
your particular pool conditions. Press and hold the LESS button for three (3) seconds. The sanitizer output display will
blank, then light up the 20%, 40%, 60% and 80% lights, four (4) total. This is a four (4) hours reverse setting. Pressing
the LESS button once within ten (10) seconds will switch off the 80% light, leaving only three (3) lights on, now at a three
(3) hours reverse setting. Wait ten (10) seconds and this mode will end automatically, returning to the original sanitizer
output display.
IntelliChlor Electronic Chlorine Generator Installation and User's Guide
Example: The self-clean cycle is set to

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic40Ic15Ic20

Table of Contents