Salt Level Status LEDs

The IECG salt level checks the pool water daily and displays the levels as follows:
Green LED: Good salt. The pool water salt level is between 2800 ppm
and 4500, and the IECG is producing chlorine. IECG salt LED should
always be showing GREEN level for better results.
Green LED (Flashing): Salt level is above 4500 ppm. Chlorine is being
produced but the salt level is too high which increases the risk of
corrosion and deterioration of pool equipment and surfaces in and around
the pool. Pool water needs to be drained and refilled one (1) foot at a
time until the salt level is below 4500 ppm.
Red LED: Low salt. The water salt level is below 2800 ppm. The IECG
will be producing chlorine at reduced efficiency. It is highly
recommended to add salt. See (*) Note below.
Red LED: Very low salt. The water salt level has fallen below 2600 ppm.
The IECG will not produce chlorine until salt is added. The IECG is OFF.
See (*) Note below.
NOTE (*): Salinity readings will be accurate after the first power up of
the IECG, following a 24 hour period. After every salt addition, proper
dilution and salinity readings should be done after the pump has been
running for at least 24 hours.
DO NOT take salinity readings when the "LOW SALT" Red LED is
flashing or during the 24 hrs. dilution period. Otherwise, readings WILL
NOT be accurate.

Status LEDs

Pwr: Shows the IntelliChlor Electronic Chlorine Generator power status:
Red: An error is occurring in the IECG. Service is needed.
Green: The IECG is operational and ready.
Cell: Shows the status of the IECG.
Green (flashing): The IECG needs to be inspected. The blades
may have calcium buildup. The IECG is not producing chlorine.
Green: IECG is good and producing chlorine
No Light: IECG is off and not producing chlorine. It may be in an
off-period of the sanitizing cycle and will return on shortly. This
light will also be blank if the water temperature is below
52° F +/-3° F (11° C +/ 1.67° C). This cold water cutoff mode
extends the blade life.
Flow: This light indicates the status of water flowing through the IECG.
Red: Insufficient water flow through the IECG, no chlorine is being produced.
Green: Sufficient water flow to produce chlorine.