The heating mode, remote shutdown, such as indoor heat exchanger temperature is
higher, the wind blowing out opportunities continue to run the waste heat.
Cool and dehumidification mode , after the compressor close, indoor machine will
continue to set the speed of operation for a period of time.

2.9 automatically model

This model does not automatically model function, emergency button cannot set the
automatic mode of operation, can use the emergency switch shutdown, remote setting the
automatic mode of indoor machine with remote signal. (emergency button only for cassette
type)

2.10 Dehumidifying method:

Remote control setting dehumidifying mode, indoor machine forced to run at low
speed(high power key or a strong bond also maintain a low wind speed), the outdoor
machine according to the refrigeration mode operation.

2.11 Self Recovery of Power Break

When the power supply is recovered after break, all preset are still effective and the
air-conditioner can run according to the original setting.
How to set/cancel
It can be set by wire remote controller YXE-C01U/YXE-C02U.
Details see Internal control parameter adjustment.

2.12 FAULT CODE

The fault code can be showed by LED on the indoor panel.
2.13 Filter clean
Filer clean led will light up when air filter is clogged with dust.
How to reset:
①Press Emergency switch;
②Press high power button for 5s;
③By wire remote controller YXE-C01U/YXE-C02U, press cancel button for 3s.