Inductance; Step Motor; Fuse - WINTAIR WAW-24/INV Technical And Service Manual

Dc inverter air conditioners
Table of Contents

Advertisement

8
.
C
H
E
C
K
I
N
G
C
O
8
.
C
H
E
C
K
I
N
G
C
O

4. INDUCTANCE

Familiar error:
1)Sound abnormality
2)Insulation resistance disqualification.

5. STEP MOTOR

5
1
Test in resistance.
TOOL: Multimeter.
Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short
circuit)or∞(open circuit).

6. FUSE

Checking continuity of fuse on PCB ASS'Y.
1) Remove the PCB ASS'Y from the electrical component box. Then pull out the fuse from the
PCB ASS'Y (Fig.1)
2) Check for continuity by a multimeter as shown in Fig.2.
7.CAPACITOR
1) Remove the lead wires from the capacitor terminals, and then place a probe on the
capacitor terminals as shown in Fig.3.
2) Observe the deflection of the pointer, setting the resistance measuring range of the
multimeter to the maximum value.
DC INVERTER AIR CONDITIONER TECHNICAL& SERVICE MANUAL V3.3
M
P
O
N
E
N
T
S
M
P
O
N
E
N
T
S
4
2
Fuse
PCB Ass'Y
Fuse
Fig.2
Fig.1
130