Target CFM Tables

CBX32MV-018/024 BLOWER PERFORMANCE
ADJUST
Jumper
1
Setting
cfm
L/s
+
715
337
NORM
670
315
580
275
CBX32MV-024/030 BLOWER PERFORMANCE
ADJUST
1
Jumper
cfm
L/s
Setting
+
800
380
NORM
725
340
655
310
CBX32MV-036 BLOWER PERFORMANCE
ADJUST
1
Jumper
cfm
L/s
Setting
+
1230
580
NORM
1120
530
1010
475
CBX32MV-048 AND CBX32MV-060 BLOWER PERFORMANCE
Pressure Range
ADJUST
1
Jumper
cfm
L/s
Setting
+
1850
875
NORM
1705
805
1560
735
CBX32MV-068 BLOWER PERFORMANCE
1
ADJUST
cfm
L/s
Jumper Setting
+
1875
885
NORM
1760
830
1550
730
NOTES − The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting.
Lennox Harmony IIIt Zone Control applications − minimum blower speed is 300 cfm (145 L/s)
0 through 0.80 in. w.g. (0 through 200 Pa) External Static Pressure Range
HEAT Speed
2
3
cfm
L/s
cfm
L/s
855
405
1000
470
770
365
900
425
700
330
800
375
0 through 0.80 in. w.g. (0 through 200 Pa) External Static Pressure Range
HEAT Speed
2
3
cfm
L/s
cfm
L/s
935
440
1070
505
850
400
975
460
765
360
880
415
0 through 0.80 in. w.g. (0 through 200 Pa) External Static Pressure Range
HEAT Speed
2
3
cfm
L/s
cfm
L/s
1335
630
1445
680
1215
575
1315
620
1185
560
1200
565
HEAT Speed
2
3
cfm
L/s
cfm
L/s
1960
925
2090
985
1800
850
1900
895
1625
765
1720
810
0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range
HEAT Speed
2
3
cfm
L/s
cfm
L/s
1975
930
2090
985
1825
860
1920
905
1650
780
1725
815
Jumper Speed Positions
4
1
cfm
L/s
cfm
L/s
1130
535
465
220
1035
490
425
200
930
440
385
180
Jumper Speed Positions
4
1
cfm
L/s
cfm
L/s
1210
570
660
310
1100
520
600
285
990
470
540
255
Jumper Speed Positions
4
1
cfm
L/s
cfm
L/s
1545
730
1090
515
1400
660
975
460
1265
595
900
425
0 through 0.80 in. w.g. (0 Through 200 Pa) External Static
Jumper Speed Positions
4
1
cfm
L/s
cfm
L/s
2150
1015
1625
765
2005
945
1425
670
1770
835
1205
570
Jumper Speed Positions
4
1
cfm
L/s
cfm
L/s
2150
1015
1640
775
2030
960
1465
690
1800
850
1250
590
Page 25
COOL Speed
2
3
cfm
L/s
cfm
L/s
690
325
900
425
620
290
825
390
560
265
735
345
COOL Speed
2
3
cfm
L/s
cfm
L/s
880
415
1100
520
800
380
1000
470
720
340
900
425
COOL Speed
2
3
cfm
L/s
cfm
L/s
1225
580
1380
650
1125
530
1275
600
1000
470
1135
535
COOL Speed
2
3
cfm
L/s
cfm
L/s
1820
860
2055
970
1625
765
1805
850
1375
650
1555
735
COOL Speed
2
3
cfm
L/s
cfm
L/s
1840
870
2075
980
1625
765
1800
850
1390
655
1560
735
4
cfm
L/s
1050
495
950
450
850
400
4
cfm
L/s
1320
625
1200
565
1080
510
4
cfm
L/s
1545
730
1400
660
1265
595
4
cfm
L/s
2145
1010
2005
945
1725
815
4
cfm
L/s
2150
1015
2000
945
1720
810
CBX32MV SERIES

Advertisement

Table of Contents
loading

This manual is also suitable for:

Variable speed air handlers cbx32mv

Table of Contents