Slope Coil In Horizontal-Left Application (Factory Ready); Slope Coil In Horizontal Right Application - Carrier FV4B Installation Instructions Manual

Fan coil for puron refrigerant
Table of Contents

Advertisement

LOW VOLT
ENTRY
OPTIONS
POWER
ENTRY OPTIONS
COIL
SUPPORT
RAIL
SLOPE COIL
6. Convert air-seal assembly for horizontal right.
a. Remove air-seal assembly from coil by removing 4 screws. (See Fig. 6.)
b. Remove air splitter (B) from coil seal assembly by removing 3 screws. (See Fig. 6-factory-shipped inset.)
c. Remove filler plate (A) and install air splitter (B) in place of filler plate.
d. Install filler plate (A) as shown in horizontal right application.
e. Remove condensate troughs (C) and install on opposite tube sheets.
f. Install hose onto plastic spout.
7. Install horizontal pan on right side of coil assembly.
FIELD
SUPPLIED
HANGING
STRAPS
UNIT
Fig. 4—Slope Coil in Horizontal-Left Application (Factory Ready)
COIL MOUNTING
SCREW
SKI
DRAINPAN
Fig. 5—Slope Coil in Horizontal Right Application
A-COIL
HORIZONTAL LEFT
PRIMARY
DRAIN
SECONDARY
DRAIN
PRIMARY DRAIN
REFRIGERANT
CONNECTIONS
SECONDARY DRAIN
—4—
PRIMARY
SECONDARY
DRAIN
DRAIN
002-005 21-IN.
006 24-IN.
FRONT SERVICE
CLEARANCE
(FULL FACE
OF UNIT)
1 3 /4 IN.
FILTER ACCESS
CLEARANCE
BLOWER
ASSEMBLY
A00096
A03001

Hide quick links:

Advertisement

Table of Contents
loading