VRE3036ZMN
• Rating (Variable): 28,000/41,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
VRE3036ZMP
• Rating (Variable): 32,000/41,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
WARNING: Fireplace must be operated only with doors fully open.
127042-01_B

SPECIFICATIONS

VRE3042ZMN
• Rating (Variable): 32,000/47,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
VRE3042ZMP
• Rating (Variable): 35,000/45,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
*For purpose of input adjustment

WIRING DIAGRAM