OPERATION Continued
Note: If pilot goes out, repeat steps 4 through 8.
9. Slightly push in and turn control knob counterclockwise
to the ON position.
10. Wait one minute and move switch to the ON position to light
burner.
Note: AUTO is only functional when using optional remote control
accessory.
11. Set flame adjustment knob to any level between HI and LO.
Control
Knob
Piezo
Ignitor
Flame Adjustment Knob
Figure 18 - Setting Control Knobs
TO TURN OFF GAS
TO APPLIANCE
1. Push switch into OFF position. The pilot will remain lit for normal
service.
2. Access control knobs.
3. Press gas control knob slightly and turn clockwise to OFF. Do not
force.
4. Close equipment shutoff valve (see Figure 14, page 10).
HAND-HELD
REMOTE OPERATION
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions, page 12.
After lighting, let pilot flame burn for about one minute. Turn
control knob to ON position. Adjust flame adjustment knob
anywhere between HI and LO. Slide the selector switch to
the REMOTE position on Remote Receiver (see Figure 19).
Note: The burner may light if hand-held remote was on when selector
switch was last turned off. You can now turn the burner on and off
with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch in the REMOTE or ON
position when the pilot is not lit. This will drain the battery.
Control Knob
Piezo
Igniter
Flame Adjustment Knob
Figure 19 - Settings for Remote Operation
127042-01_B
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height.
Alterations may have occurred during shipping and handling. Call a
qualified service person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2" above the pilot
flame as shown in Figure 20. The thermocouple must be at a height
of about 1/8" above the pilot flame. The flame from the pilot burner
must extend beyond both the thermocouple and thermopile.
If you pilot assembly does not meet these requirements:
• turn fireplace off (see To Turn Off Gas to Appliance)
• see Troubleshooting, page 16
BURNER FLAME PATTERN
Figure 21 shows correct burner flame pattern.
NOTICE: Do not mistake orange flames with yellow
tipping. Dirt or other fine particles are burned by ap-
pliance, causing brief patches of orange flame.
If burner flame pattern is incorrect, as shown in Figure 22.
• turn appliance off (see To Turn Off Gas to Appliance)
• see Troubleshooting, page 16
REMOTE
OFF
ON
Selector Switch in
REMOTE Position
Superiorfireplaces.US.com

INSPECTING BURNERS

Thermopile
3/8" to 1/2"
Piezo
Ignitor
Figure 20 - Pilot Assembly
Yellow Flames with
Orange Streaks
Figure 21 - Correct Burner Flame Pattern
Figure 22 - Incorrect Burner Flame Pattern
Pilot Burner
1/8"
Thermocouple
Dark Orange
Flames
13